The John N. Insall Award: Functional Versus Mechanical Alignment in Total Knee Arthroplasty: A Randomized Controlled Trial
OrtopediaPor ScienceMed · · a partir do resumo dos autores
Resumo original em inglês
O que aconteceu
Mechanical alignment (MA) in total knee arthroplasty is regarded as a gold standard; however, some patients report dissatisfaction postsurgery. Functional alignment (FA) is a potential alternative, integrating kinematic alignment (KA) principles with preresection bone balancing within defined boundaries. The use of FA aims to improve outcomes by restoring native joint lines and optimizing soft-tissue balance. However, comparative evidence is limited.
This prospective, randomized controlled trial compared MA (n = 121) and FA (n = 123) in robotic-assisted total knee arthroplasty. For MA, components were positioned perpendicular to the limb mechanical axis, with soft-tissue releases to achieve balance. For FA, initial virtual component positioning was used to match native knee anatomy, with adjustments for soft-tissue balance before bone cuts. The primary outcome was the forgotten joint score (FJS). Outcomes were compared with a mixed-model analysis of variance.
O que encontraram
At the 2-year follow-up, the mean FJS was comparable (MA: 64.4 ± 30.1 versus FA: 70.1 ± 25.6, P = 0.10). The MA cases had more soft-tissue releases than FA (65 versus 16%, P < 0.001). Compared to MA patients, FA patients had higher Knee Injury and Osteoarthritis Outcome (KOOS) Symptoms (86.6 ± 12.9 versus 82.5 ± 14.0, P = 0.01) and KOOS-Quality of Life scores (76.1 ± 20.3 versus 70.7 ± 22.7, P = 0.03). More FA patients "would recommend" the procedure (94 versus 82%, P < 0.01). For patients who had preoperative Coronal Plane Alignment of the Knee Type I, FA had higher FJS (71.3 ± 24.8 versus 56.8 ± 31.6, P = 0.02) and KOOS-Quality of Life (76.4 ± 21.7 versus 64.2 ± 19.2, P = 0.02) than MA. No other differences were seen in patient-reported outcomes (Oxford Knee Score, KOOS, EuroQol-5 Dimensions, Pain Visual Analog Scale), clinical outcomes (length of stay, functional physio tests), reoperations, or implant survivorship (FA: 1 versus MA: 0 revisions).
Por que isso importa
While FA required fewer soft-tissue releases compared to mechanical alignment, at 2 years patient-reported and clinical outcomes were similar. The use of FA may provide improved outcomes for a specific subgroup of patients based on their preoperative alignment.
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
The John N. Insall Award: Functional Versus Mechanical Alignment in Total Knee Arthroplasty: A Randomized Controlled Trial
Simon W Young, Mei Lin Tay, Kohei Kawaguchi, Rupert van Rooyen, Matthew L Walker, William J Farrington, Ali Bayan
Descritores MeSH
- Knee Joint
- Arthroplasty, Replacement, Knee
- Osteoarthritis, Knee
- Robotic Surgical Procedures
- Humans
- Knee Prosthesis
- Aged
- Middle Aged
- Prospective Studies
- Range of Motion, Articular
Veja também
Estudos relacionados
- Functional, patient-reported, and radiographic outcomes of kinematic versus mechanical alignment in robotic total knee arthroplasty: A systematic review and meta-analysis
- Robot-assisted total knee arthroplasty demonstrates superior radiological but comparable clinical outcomes compared to conventional techniques: A meta-analysis of prospective studies
- Does the Use of a Robotic Gap-tensioning System Improve Functional Outcomes After TKA? A Randomized Clinical Trial
- Functional alignment restores native kinematics more consistently than mechanical axis alignment in total knee arthroplasty
- Alinhamento funcional versus alinhamento mecânico na artroplastia total do joelho: metanálise de ensaios controlados randomizados
- O alinhamento funcional na artroplastia total robótica do joelho proporciona resultados favoráveis e revisões precoces mínimas: revisão sistemática e metanálise