Results of a Prospective Randomized Multicenter Study Comparing Indocyanine Green (ICG) Fluorescence Combined with a Standard Tracer Versus ICG Alone for Sentinel Lymph Node Biopsy in Early Breast Cancer: The INFLUENCE Trial
DermatologiaPor ScienceMed · · a partir do resumo dos autores
Resumo original em inglês
O que aconteceu
For clinically node-negative early breast cancer patients, sentinel lymph node biopsy (SLNB) using dual localization with blue dye and radioisotope (RI) is currently standard of care. Documented disadvantages with these tracers have prompted exploration of alternative agents such as fluorescent indocyanine green (ICG), which demonstrates high detection rates combined with other tracers. Results of a randomized study evaluating ICG as a single tracer for SLN identification are presented.
Overall, 100 patients with unilateral, clinically node-negative, biopsy-proven invasive breast cancer (≤5 cm) scheduled for SLNB were recruited in two separate randomized cohorts, with 50 patients receiving ICG alone. Cohort 1 received ICG alone (n = 25) or combined with RI [Technetium99] (n = 25), while Cohort 2 received ICG alone (n = 25) or combined with blue dye (n = 25). The primary outcome was sensitivity for SLN identification.
O que encontraram
Among evaluable patients (n = 97), the overall SLN identification rate was 96.9% (ICG alone = 97.9%; ICG + RI = 100%; ICG + blue dye = 92%). Node positivity rates were 14.9% for ICG alone, 16% for ICG combined with RI, and 20% for ICG combined with blue dye. There were no significant differences (p < 0.05) in performance parameters, with ICG alone being non-inferior to tracer combinations for procedural node positivity rates when adjusted for specific factors.
Por que isso importa
These results support potential use of ICG as a sole tracer agent for routine SLNB, thereby avoiding disadvantages of RI and/or blue dye. The latter can be safely withheld as a co-tracer without compromising detection of positive nodes in primary surgical patients.
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
Results of a Prospective Randomized Multicenter Study Comparing Indocyanine Green (ICG) Fluorescence Combined with a Standard Tracer Versus ICG Alone for Sentinel Lymph Node Biopsy in Early Breast Cancer: The INFLUENCE Trial
Vassilis Pitsinis, Rahul Kanitkar, Alessio Vinci, Wen Ling Choong, John Benson
Descritores MeSH
- Indocyanine Green
- Coloring Agents
- Breast Neoplasms
- Sentinel Lymph Node Biopsy
- Aged
- Female
- Follow-Up Studies
- Fluorescent Dyes
- Fluorescence
- Aged, 80 and over
Veja também
Estudos relacionados
- Uso de fluorescência verde indocianina versus corante patente azul V para biópsia de linfonodo sentinela no câncer de mama precoce, um ensaio controlado randomizado
- Assessing the comparative efficacy of sentinel lymph node detection techniques in vulvar cancer: a systematic review and meta-analysis
- Indocyanine green fluorescence versus blue dye, technetium-99M, and the dual-marker combination of technetium-99M + blue dye for sentinel lymph node detection in early breast cancer-meta-analysis including consistency analysis
- Meta-analysis of the application value of indocyanine green fluorescence imaging in guiding sentinel lymph node biopsy for breast cancer