Radiation Exposure in Minimally Invasive Cervical Spine Surgery: A Systematic Review
Radiologia e ImagemPor ScienceMed · · a partir do resumo dos autores
Resumo original em inglês
O que aconteceu
Minimally invasive cervical spine surgery (MIS-CSS) relies heavily on intraoperative fluoroscopic imaging, raising concerns about radiation exposure to patients and surgical staff. Unlike lumbar MIS, cervical-specific radiation exposure has not been systematically reviewed, despite distinct anatomical considerations, including proximity to the thyroid gland and lens of the eye. This review aims to quantify intraoperative radiation exposure during MIS cervical spine procedures and evaluate available dose-reduction strategies.
A systematic literature search was conducted across PubMed/MEDLINE, Scopus, and Google Scholar in April 2026 following PRISMA 2020 guidelines. Studies reporting original quantitative radiation data during minimally invasive cervical spine procedures in adult patients (≥10 patients) were included. Quality was assessed using the MINORS tool and the JBI checklist.
O que encontraram
Seven studies encompassing 380 patients were included. Procedures comprised ACDF (four studies), minimally invasive posterior cervical laminoforaminotomy (two studies), and CT-navigated cervical instrumentation (one study). Patient effective doses during ACDF ranged from 0.015 to 1.3 mSv, with thyroid doses of 0.194-0.290 mGy. Standalone ACDF reduced patient dose by 36-58% compared to plated ACDF (p < 0.001). Navigation-assisted posterior cervical foraminotomy achieved a median fluoroscopy time of 10 s with negligible staff exposure. Surgeon per-procedure exposure during cervical discectomy (chest 0.122 µSv, lens 3.1 µSv, hands 7.1 µSv) was approximately half that of lumbar discectomy.
Por que isso importa
Radiation doses during individual MIS cervical procedures appear to be within occupational safety limits, though the current evidence is insufficient to establish definitive dose thresholds. Standalone implant designs and intraoperative navigation represent effective, complementary dose-reduction strategies. Standardized prospective research is needed to establish cervical-specific radiation safety benchmarks.
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
Radiation Exposure in Minimally Invasive Cervical Spine Surgery: A Systematic Review
Dong Hun Kim, Jung-Woo Hur, Jae Taek Hong
Descritores MeSH
- Cervical Vertebrae
- Radiation Exposure
- Minimally Invasive Surgical Procedures
- Occupational Exposure
- Humans
- Fluoroscopy
- Radiation Dosage
Veja também
Estudos relacionados
- SCAI/ASE/HRS/SIR/SVS Expert Consensus Statement on Enhanced Radiation Protection: Time for Mandatory and Urgent Action
- The impact of augmented reality on radiation exposure during spine surgery: a systematic review
- Eye Lens Radiation Exposure During TAVI: Current Evidence and Imaging-Based Strategies for Dose Reduction
- Comparison of Radiation Exposure to X-Ray Between Left and Right Radial Approach During Coronary Procedures: A Meta-Analysis Based on Randomized Controlled Trials