Several modifications to the original Grammont reverse shoulder arthroplasty (RSA) design have been proposed to prevent distinctive issues, such as both glenoid and humeral lateralization. The aim of this systematic review was to determine rates of problems, complications, reoperations, and revisions after onlay lateralized humeral stem RSA, hypothesizing that these are design related.
This systematic review was performed in accordance with the PRISMA statement guidelines. A literature search was conducted (1 January 2000 to 14 April 2020) using PubMed, Cochrane Reviews, Scopus, and Google Scholar, employing several combinations of keywords: "reverse shoulder arthroplasty," "reverse shoulder prosthesis," "inverse shoulder arthroplasty," "inverse shoulder prosthesis," "problems," "complications," "results," "outcomes," "reoperation," and "revision."
Systematic review IV.
O que encontraram
Thirty-one studies with 4893 RSA met inclusion criteria. The 892 postoperative problems and 296 postoperative complications represented overall problem and complication rates of 22.7% and 7.5%, respectively. Forty-one reoperations and 63 revisions resulted, with overall reoperation and revision rates of 1.7% and 2.6%, respectively.
Por que isso importa
Problem, complication, and reintervention rates proved acceptable when implanting a high humeral lateralization stem RSA. The most frequent problem was scapular notching (12.6%), and the most common postoperative complication was scapular stress fracture (1.8%). An overall humeral complication rate of 1.9% was identified, whereas no humeral fractures or stem loosening were reported with short stems. Infections (1.3%) were the most common reason for component revision, followed by instability (0.8%).
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
Problems, complications, and reinterventions in 4893 onlay humeral lateralized reverse shoulder arthroplasties, a systematic review: part II-problems and reinterventions
Francesco Ascione, Alfredo Schiavone Panni, Adriano Braile, Katia Corona, Giuseppe Toro, Nicola Capuano, Alfonso M Romano
Descritores MeSH
- Shoulder Joint
- Arthroplasty, Replacement, Shoulder
- Shoulder Prosthesis
- Reoperation
- Retrospective Studies
- Range of Motion, Articular
- Treatment Outcome
- Humans
- Humerus
Veja também
Estudos relacionados
- Reverse shoulder arthroplasty in the setting of massive proximal humeral bone loss: a systematic review
- Problems, complications, and reinterventions in 4893 onlay humeral lateralized reverse shoulder arthroplasties: a systematic review (part I-complications)
- Humeral Component Version Has No Effect on Outcomes Following Reverse Total Shoulder Arthroplasty: A Prospective, Double-Blinded, Randomized Controlled Trial
- Comparative glenoid reconstruction strategies in reverse shoulder arthroplasty: a meta-analysis of standard reconstruction, bony increased offset, and metal-augmented increased offset techniques