ScienceMed®
Imagem de arquivo, ilustrativa: Radiografia de um ombro normal: a cabeça do úmero diante da cavidade glenoide

Problems, complications, and reinterventions in 4893 onlay humeral lateralized reverse shoulder arthroplasties: a systematic review (part I-complications)

Ortopedia
Imagem de arquivo, ilustrativa — não é do estudo. Radiografia de um ombro normal: a cabeça do úmero diante da cavidade glenoide. Mikael Häggström · CC0 · Wikimedia Commons

Revisão sistemáticaNível 1 · Evidência consolidadaJournal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology8 jul 202120 citações

Por ScienceMed · · a partir do resumo dos autores

Salvar

Resumo original em inglês

O que aconteceu

Several modifications to the original Grammont reverse shoulder arthroplasty (RSA) design have been proposed to prevent distinctive issues, such as both glenoid and humeral lateralization. The aim of this systematic review was to determine rates of problems, complications, reoperations, and revisions after onlay lateralized humeral stem RSA, hypothesizing that these are design related.

This systematic review was performed in accordance with the PRISMA statement guidelines. A literature search was conducted (01.01.2000-14.04.2020) using PubMed, Cochrane Reviews, Scopus, and Google Scholar employing several combinations of keywords: "reverse shoulder arthroplasty," "reverse shoulder prosthesis," "inverse shoulder arthroplasty," "inverse shoulder prosthesis," "problems," "complications," "results," "outcomes," "reoperation," "revision."

Systematic review IV.

O que encontraram

Thirty-one studies with 4893 RSA met inclusion criteria. The 892 postoperative problems and 296 postoperative complications represented overall problem and complication rates of 22.7% and 7.5%, respectively. Forty-one reoperations and 63 revisions resulted, with an overall reoperation rate of 1.7% and overall revision rate of 2.6%.

Por que isso importa

Problem, complication, and reintervention rates proved acceptable when implanting a high humeral lateralization stem in RSA. The most frequent problem was scapular notching (12.6%), and the most common postoperative complication was scapular stress fracture (1.8%). An overall humeral complication rate of 1.9% was identified, whereas short stems reported no humeral fractures or stem loosening. Infections (1.3%) proved to be the most common reason for component revision, and instability had a complication rate of 0.8%.

Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.

O estudo original

Problems, complications, and reinterventions in 4893 onlay humeral lateralized reverse shoulder arthroplasties: a systematic review (part I-complications)

Francesco Ascione, Alfredo Schiavone Panni, Adriano Braile, Katia Corona, Giuseppe Toro, Nicola Capuano, Alfonso M Romano

Descritores MeSH

  • Shoulder Prosthesis
  • Arthroplasty, Replacement, Shoulder
  • Humerus
  • Postoperative Complications
  • Shoulder Fractures
  • Shoulder Joint
  • Humans
  • Retrospective Studies
  • Scapula
  • Reoperation

Veja também