ScienceMed®
Imagem de arquivo, ilustrativa: Pastilha de silício de um processador Intel Pentium II ao microscópio

O efeito de um novo dispositivo de feedback vestível sobre o treinamento de ressuscitação cardiopulmonar em estudantes de medicina: um ensaio controlado randomizado de agrupamento de três braços

Emergência e Terapia Intensiva
Imagem de arquivo, ilustrativa — não é do estudo. Pastilha de silício de um processador Intel Pentium II ao microscópio. Martijn Boer · domínio público · Wikimedia Commons

Ensaio clínico randomizadoNível 2 · Nova evidênciaFrontiers in public health21 jul 20260 citações

Por ScienceMed · · · a partir do resumo dos autores

Salvar

Resumo original em inglês

O que aconteceu

While real-time feedback devices are proven to improve skill mastery in CPR training, current options are often suboptimal due to high costs, skin irritation, and single-functionality constraints. To overcome these limitations, we engineered a novel wearable feedback device, the accuracy of which was validated in our prior research. Furthermore, we conceptualized a hybrid training paradigm combining real-time feedback with deliberate practice. Given the current lack of efficacy data for this approach, this study aims to assess the device's real-world training performance and investigate whether this hybrid training approach can further optimize resuscitation training outcomes.

Students from Chongqing Medical University were recruited and randomly assigned to three groups: traditional training (Group A), real-time feedback training (Group B), or real-time feedback plus deliberate practice training (Group C). All participants were required to perform 2 min of chest compressions on CPR manikins. The primary outcomes were the proportion of correct compression depth (50-60 mm) and adequate compression rate (100-120 min-1). The secondary outcomes were chest compression depth (mm), chest compression rate (min-1), and the proportion of correct compression release.

O que encontraram

A total of 618 participants were randomly assigned to Group A (n = 210), Group B (n = 204), and Group C (n = 204). The proportion of correct compression depth in Group B was higher than that in Group A (mean [SD], 82.55 [12.67] % vs. 71.54 [22.28] %, mean difference [95% CI], -11.0 [-14.5 to -7.5] %, p 0.05).

Por que isso importa

In conclusion, within the academic setting of a medical university, this novel feedback device improved CPR performance in compression depth and rate among medical students compared to traditional training. Furthermore, the hybrid training method combining real-time feedback and deliberate practice further enhanced training efficacy regarding chest compression depth in this population. However, these findings require independent replication in broader populations and diverse clinical settings before widespread implementation recommendations can be made.

Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.

O estudo original

The effect of a novel wearable feedback device on cardiopulmonary resuscitation training in medical students: a three-arm cluster randomized controlled trial

Enze Liu, Liyuan Gan, Wenwen Ma, Mo Chen, Chen Zhang, Xintao Huang, Huisheng Deng

Descritores MeSH

  • Feedback
  • Students, Medical
  • Cardiopulmonary Resuscitation
  • Wearable Electronic Devices
  • Humans
  • Male
  • Manikins
  • Young Adult
  • Adult
  • Clinical Competence

Veja também

Estudos relacionados