Nylon clip wear and patient satisfaction in implant-retained mandibular overdenture using PEEK bar versus metal bar: a one-year randomized clinical study
MedicinaResumo original em inglês
O que aconteceu
STATEMENT OF PROBLEM: Nylon clip wear affects the retention of implant-retained overdenture. PURPOSE: The purpose of the present investigation was to determine the wear of nylon clips and patient satisfaction with either a cobalt-chromium (Co-Cr) metal bar or a milled polyether ether ketone (PEEK) bar in mandibular dentures supported by two implant-retained mandibular overdentures over a one-year clinical study. MATERIALS AND METHODS: Twenty edentulous patients were randomly divided into two groups ten patients in each group. Group I (Co-Cr metal bar with nylon clip) and Group II (PEEK bar with nylon clip). In both groups, two implants were placed in the canine–premolar region using a delayed loading protocol. The primary outcome was Nylon clip wear, it was evaluated using volumetric change and surface roughness assessment at insertion, three months, six months, nine months, and one year. Patient satisfaction was evaluated at six months and one year using a visual analog scale (VAS). Data were collected and statistically analyzed to compare the final outcomes between the two groups. RESULTS: The metal group showed significantly higher roughness and volumetric changes with volumetric changes reached 7.49 μm ± 0.47 after 12 months (P=.0001) compared to the PEEK group that reached 7.21 μm ± 0.43 with no difference was found between them at 12 months (P = .188). Patient satisfaction scores were significantly higher in the PEEK group, regarding retention, stability, comfort, and speaking at both 6 months and 1 year (P=.04). CONCLUSIONS: Nylon clips showed clinically acceptable wear performance with both PEEK and metal bars after 1 year, and the PEEK bar demonstrated superior surface properties and patient satisfaction, especially in the first 6 months of the study. TRIAL REGISTRATION: The study was approved by the Research Ethics Committee of the faculty of dentistry, Cairo University (No 94/23) and registered in the Clinical Trials.gov (NCT06909435). Trial Registration date is 27-03-2025.
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
Nylon clip wear and patient satisfaction in implant-retained mandibular overdenture using PEEK bar versus metal bar: a one-year randomized clinical study
Sara Medhat Mohamed, Doaa Amr Heshmat Rostom
Descritores MeSH
- Ketones
- Nylons
- Polyethylene Glycols
- Denture Retention
- Denture, Overlay
- Patient Satisfaction
- Dental Prosthesis, Implant-Supported
- Dental Restoration Wear
- Middle Aged
- Polymers
Estudos relacionados
- Retention Comparison of Milled Cobalt Chromium and Polyetheretherketone Secondary Telescopic Crowns in Implant-Retained Mandibular Overdentures: A Randomized Clinical Trial
- A randomized controlled pilot trial comparing peri-implant tissue health beneath CAD/CAM-milled PEEK versus cobalt-chromium telescopic crowns for mandibular overdentures
- Patient satisfaction and oral health-related quality of life for four implant-assisted mandibular overdentures fabricated with CAD/CAM milled poly methyl methacrylate, CAD/CAM-milled poly ether ether ketone, or conventional poly methyl methacrylate: A crossover clinical trial
- Clinical and Prosthetic Outcomes of Titanium Zirconium Versus PEEK Composite Maxillary Fixed Prostheses Opposing Distal Extension Partial Dentures: Comparative Clinical Study