A randomized controlled pilot trial comparing peri-implant tissue health beneath CAD/CAM-milled PEEK versus cobalt-chromium telescopic crowns for mandibular overdentures
MedicinaResumo original em inglês
O que aconteceu
This pilot randomized clinical trial compared peri-implant tissue health around milled cobalt-chromium (CoCr) versus polyether ether ketone (PEEK) secondary telescopic crowns in implant-retained mandibular overdentures over 12 months.
Twelve completely edentulous patients received two implants each. After randomization, secondary crowns were fabricated from milled CoCr (n = 6 patients) or PEEK (n = 6 patients). Assessor-blinded outcome assessments such as marginal bone loss (MBL), probing depth (PD), and plaque index (PI) were performed at baseline, 6, 9, and 12 months post-loading. Statistical analysis used the patient as the unit of analysis.
O que encontraram
No statistically significant inter-group differences were found at any time point. At 12 months, mean MBL was 0.48 ± 0.15 mm for CoCr and 0.45 ± 0.16 mm for PEEK (p = 0.735). PD increased over time within groups but remained comparable between groups (CoCr: 2.58 ± 0.58 mm, PEEK: 2.33 ± 0.41 mm at 12 months; p = 0.411). PI scores also showed no significant inter-group differences (p > 0.05).
Por que isso importa
Over 12 months, milled PEEK and CoCr secondary telescopic crowns demonstrated comparable peri-implant tissue health. PEEK presents a viable metal-free alternative for this application. These preliminary findings warrant confirmation in larger, long-term studies.
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
A randomized controlled pilot trial comparing peri-implant tissue health beneath CAD/CAM-milled PEEK versus cobalt-chromium telescopic crowns for mandibular overdentures
Iman A El Asfahani, Amr Khalifa, Doaa Tawfik, Emad Agamy, Mahmoud G Salloum
Descritores MeSH
- Dental Prosthesis, Implant-Supported
- Chromium Alloys
- Crowns
- Denture, Overlay
- Ketones
- Polyethylene Glycols
- Female
- Humans
- Dental Prosthesis Design
- Male
Estudos relacionados
- Retention Comparison of Milled Cobalt Chromium and Polyetheretherketone Secondary Telescopic Crowns in Implant-Retained Mandibular Overdentures: A Randomized Clinical Trial
- Nylon clip wear and patient satisfaction in implant-retained mandibular overdenture using PEEK bar versus metal bar: a one-year randomized clinical study
- Surface Texture and Clinical Performance of Milled BioHPP Polyetheretherketone (PEEK) Single Posterior Crowns Veneered with Two Different Techniques: Randomized Controlled Clinical Trial
- Clinical and Prosthetic Outcomes of Titanium Zirconium Versus PEEK Composite Maxillary Fixed Prostheses Opposing Distal Extension Partial Dentures: Comparative Clinical Study