Convolutional neural network performance compared to radiologists in detecting intracranial hemorrhage from brain computed tomography: A systematic review and meta-analysis
NeurologiaPor ScienceMed · · a partir do resumo dos autores
Resumo original em inglês
O que aconteceu
To compare the diagnostic accuracy of convolutional neural networks (CNN) with radiologists as the reference standard in the diagnosis of intracranial hemorrhages (ICH) with non contrast computed tomography of the cerebrum (NCTC).
PubMed, Embase, Scopus, and Web of Science were searched for the period from 1 January 2012 to 20 July 2020; eligible studies included patients with and without ICH as the target condition undergoing NCTC, studies had deep learning algorithms based on CNNs and radiologists reports as the minimum reference standard. Pooled sensitivities, specificities and a summary receiver operating characteristics curve (SROC) were employed for meta-analysis.
O que encontraram
5,119 records were identified through database searching. Title-screening left 47 studies for full-text assessment and 6 studies for meta-analysis. Comparing the CNN performance to reference standards in the retrospective studies found a pooled sensitivity of 96.00% (95% CI: 93.00% to 97.00%), pooled specificity of 97.00% (95% CI: 90.00% to 99.00%) and SROC of 98.00% (95% CI: 97.00% to 99.00%), and combining retrospective and studies with external datasets found a pooled sensitivity of 95.00% (95% CI: 91.00% to 97.00%), pooled specificity of 96.00% (95% CI: 91.00% to 98.00%) and a pooled SROC of 98.00% (95% CI: 97.00% to 99.00%).
Por que isso importa
This review found the diagnostic performance of CNNs to be equivalent to that of radiologists for retrospective studies. Out-of-sample external validation studies pooled with retrospective studies found CNN performance to be slightly worse. There is a critical need for studies with a robust reference standard and external data-set validation.
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
Convolutional neural network performance compared to radiologists in detecting intracranial hemorrhage from brain computed tomography: A systematic review and meta-analysis
Mia Daugaard Jørgensen, Ronald Antulov, Søren Hess, Simon Lysdahlgaard
Descritores MeSH
- Neural Networks, Computer
- Radiologists
- Retrospective Studies
- Tomography, X-Ray Computed
- Intracranial Hemorrhages
- Sensitivity and Specificity
- Humans
Veja também
Estudos relacionados
- Impact of Artificial Intelligence Assistance on Chest CT Interpretation Times: A Prospective Randomized Study
- Aprendizagem profunda versus radiologistas para dissecção aguda da aorta na TC: revisão sistemática e metanálise de rede
- CT-Based Radiomics and Deep Learning for Preoperative Thyroid Nodule Classification: A Systematic Review, Meta-analysis, and Radiologist Comparison
- A systematic review of comparisons of AI and radiologists in the diagnosis of HCC in multiphase CT: implications for practice