ScienceMed®
Imagem de arquivo, ilustrativa: Músculo cardíaco em corte longitudinal, com os discos intercalares, ao microscópio óptico

Artificial Intelligence-Assisted Point-of-Care Ultrasound for Evaluating Left Ventricular Ejection Fraction: A Systematic Review of Prospective Observational Studies

Emergência e Terapia Intensiva
Imagem de arquivo, ilustrativa — não é do estudo. Músculo cardíaco em corte longitudinal, com os discos intercalares, ao microscópio óptico. Berkshire Community College Bioscience Image Library · CC0 · Wikimedia Commons

Revisão sistemáticaNível 1 · Evidência consolidadaJournal of cardiothoracic and vascular anesthesia12 fev 20264 citações

Por ScienceMed · · a partir do resumo dos autores

Salvar

Resumo original em inglês

O que aconteceu

Artificial intelligence (AI) embedded in point-of-care ultrasound (POCUS) could reduce operator dependence in left ventricular ejection fraction (LVEF) assessment and accelerate bedside decision making by non-cardiologists and non-radiologists. Prospective comparative studies evaluating real-time AI-assisted POCUS for LVEF across point-of-care settings were systematically reviewed. The PubMed/MEDLINE, Embase, and Cochrane databases were searched from inception to June 11, 2025. The authors included prospective analytical observational studies in intensive care unit (ICU), emergency department, perioperative, ward, or home settings that used AI during image acquisition and/or interpretation to estimate LVEF in real time against a reference standard. Risk of bias was appraised using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. Because of heterogeneity, the findings were narratively synthesized. Twelve studies met the inclusion criteria across ICU, emergency department, perioperative, ward, and community settings. For continuous outcomes, agreement (r) between AI-derived and reference LVEF ranged from 0.56 to 0.92 and intraclass correlation coefficients ranged from 0.84 to 0.94. Bland-Altman analyses demonstrated broad limits of agreement, from approximately -31.8% to +20.0%, often indicating a tendency for AI to underestimate LVEF compared with reference measures. For categorical classification at a 50% threshold, sensitivities ranged from 70% to 93%; specificities, from 89% to 100%; and areas under the receiver operating characteristic curves, from 0.85 to 0.98. Weighted κ values ranged from 0.49 to 0.83. No study achieved a low risk of bias across all QUADAS-2 domains. AI-assisted POCUS can approximate reference LVEF and reasonably classify reduced LVEF at the bedside, supporting its use as a screening and triage tool in settings in which comprehensive echocardiography is not immediately available. Future studies should adopt intention-to-diagnose designs, standardize the Simpson biplane reference, minimize test delay, report calibration and failure rates, and incorporate image quality feedback.

Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.

O estudo original

Artificial Intelligence-Assisted Point-of-Care Ultrasound for Evaluating Left Ventricular Ejection Fraction: A Systematic Review of Prospective Observational Studies

Joe Zako, Shi Shu Wang, Tudor Pintilei, Julien Burey, Thomas M Hemmerling, Louis Morisson, André Denault, Pascal Laferrière-Langlois

Descritores MeSH

  • Stroke Volume
  • Ventricular Function, Left
  • Point-of-Care Systems
  • Artificial Intelligence
  • Observational Studies as Topic
  • Humans
  • Prospective Studies
  • Ultrasonography

Veja também

Estudos relacionados