
Artificial Intelligence-Assisted Point-of-Care Ultrasound for Evaluating Left Ventricular Ejection Fraction: A Systematic Review of Prospective Observational Studies
Emergência e Terapia IntensivaPor ScienceMed · · a partir do resumo dos autores
Resumo original em inglês
O que aconteceu
Artificial intelligence (AI) embedded in point-of-care ultrasound (POCUS) could reduce operator dependence in left ventricular ejection fraction (LVEF) assessment and accelerate bedside decision making by non-cardiologists and non-radiologists. Prospective comparative studies evaluating real-time AI-assisted POCUS for LVEF across point-of-care settings were systematically reviewed. The PubMed/MEDLINE, Embase, and Cochrane databases were searched from inception to June 11, 2025. The authors included prospective analytical observational studies in intensive care unit (ICU), emergency department, perioperative, ward, or home settings that used AI during image acquisition and/or interpretation to estimate LVEF in real time against a reference standard. Risk of bias was appraised using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. Because of heterogeneity, the findings were narratively synthesized. Twelve studies met the inclusion criteria across ICU, emergency department, perioperative, ward, and community settings. For continuous outcomes, agreement (r) between AI-derived and reference LVEF ranged from 0.56 to 0.92 and intraclass correlation coefficients ranged from 0.84 to 0.94. Bland-Altman analyses demonstrated broad limits of agreement, from approximately -31.8% to +20.0%, often indicating a tendency for AI to underestimate LVEF compared with reference measures. For categorical classification at a 50% threshold, sensitivities ranged from 70% to 93%; specificities, from 89% to 100%; and areas under the receiver operating characteristic curves, from 0.85 to 0.98. Weighted κ values ranged from 0.49 to 0.83. No study achieved a low risk of bias across all QUADAS-2 domains. AI-assisted POCUS can approximate reference LVEF and reasonably classify reduced LVEF at the bedside, supporting its use as a screening and triage tool in settings in which comprehensive echocardiography is not immediately available. Future studies should adopt intention-to-diagnose designs, standardize the Simpson biplane reference, minimize test delay, report calibration and failure rates, and incorporate image quality feedback.
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
Artificial Intelligence-Assisted Point-of-Care Ultrasound for Evaluating Left Ventricular Ejection Fraction: A Systematic Review of Prospective Observational Studies
Joe Zako, Shi Shu Wang, Tudor Pintilei, Julien Burey, Thomas M Hemmerling, Louis Morisson, André Denault, Pascal Laferrière-Langlois
Descritores MeSH
- Stroke Volume
- Ventricular Function, Left
- Point-of-Care Systems
- Artificial Intelligence
- Observational Studies as Topic
- Humans
- Prospective Studies
- Ultrasonography
Veja também
Estudos relacionados
- Automated and reference methods for the calculation of left ventricular outflow tract velocity time integral or ejection fraction by non-cardiologists: a systematic review on the agreement of the two methods
- Efeitos cardíacos dependentes da duração do uso de esteroides androgênicos anabólicos em atletas treinados pela força: revisão sistemática e meta-análise
- Diagnostic accuracy of AI-assisted point-of-care ultrasound for abdominal free fluid detection in FAST trauma assessment: a systematic review and meta-analysis
- Point-of-Care Ultrasound Imaging for Automated Detection of Abdominal Haemorrhage: A Systematic Review