O que aconteceu
The role of cardiovascular implantable electronic device (CIED)-derived activity to predict implantable cardioverter-defibrillator (ICD) therapy or death is not known.
We aimed to assess CIED-derived activity to predict clinical outcomes.
In 1500 patients enrolled in MADIT-RIT, CIED-derived patient activity was acquired daily, then averaged for the first 30 days following randomization to predict inappropriate/appropriate therapy or death. Kaplan-Meier analysis and Cox proportional regression models were used to evaluate inappropriate/appropriate therapy, heart failure, or death by 30-day CIED-derived patient activity quintiles.
O que encontraram
There were 1463 patients with CIED activity data (98%). Patients in the highest quintile (Q5) of activity (more active) had the highest rate of inappropriate therapy, 21% at 2 years, as compared to 7%-11% in the other 4 quintiles (P 2 hours/day, 2%-3% mortality) (P < .001). Patients with the lowest level of activity (Q1) had a 2.02 times higher risk of mortality (95% CI: 1.21-3.38, P = .007), and they had an 82% higher risk of heart failure hospitalization (95% CI: 1.28-2.57, P = .001).
Por que isso importa
High CIED-derived 30-day median patient activity predicted inappropriate therapy, while low patient activity predicted mortality and heart failure in ICD and cardiac resynchronization therapy with defibrillator patients enrolled in MADIT-RIT. Device-derived activity assessment could serve as a useful predictor of outcomes.
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
Utility of cardiovascular implantable electronic device-derived patient activity to predict clinical outcomes
Spencer Z Rosero, Arwa Younis, Paul Jones, Scott McNitt, Ilan Goldenberg, Wojciech Zareba, Kenneth Stein, Valentina Kutyifa
Descritores MeSH
- Heart Failure
- Defibrillators, Implantable
- Tachycardia, Ventricular
- Humans
- Male
- Middle Aged
- Aged
- Risk Factors
- Global Health
- Incidence
Veja também
Estudos relacionados
- Lipoprotein(a) and the Risk of Heart Failure: A Dose-Response Meta-Analysis
- Association of clonal haematopoiesis with heart failure incidence and outcomes: A systematic review and meta-analysis
- Ventricular arrhythmias following left ventricular assist device implantation: a systematic review and meta-analysis of incidence and clinical impact
- Association between tricuspid regurgitation and heart failure outcomes: A meta-analysis