Using wearable technology for Posture Regulation to Improve Surgical Ergonomics in the paediatric operating room: the UPRISE trial: a pilot study
OrtopediaPor ScienceMed · · a partir do resumo dos autores
Resumo original em inglês
O que aconteceu
The rising prevalence of work-related musculoskeletal disorders has numerous physical, financial, and mental repercussions for surgeons. This study aims to establish whether the use of a wearable posture device can improve the operating time spent in suboptimal, high-risk postures.
Surgeons were recruited in Phase 1 of this prospective randomised study and baseline postural data was obtained. In Phase 2, participants were randomised to receive either a traditional educational workshop or intraoperative vibrations from the device to correct postural lapses. During minor elective day cases, intraoperative postural data was collected and stratified by forward flexion angle, into five risk categories (negligible to very high). Participants' experience with the sensor was also assessed.
O que encontraram
A total of 100 surgical procedures (Phase 1: n = 50; Phase 2: n = 50) were performed by eight surgeons of varying seniority. Exposure to the educational intervention increased time spent in suboptimal posture (Phase 1 vs. Phase 2); 47.5% vs. 67.8%, p = 0.05. However, the vibrational intervention significantly reduced this time; 50.0% vs. 20.7%, p = 0.005. Procedure type didn't influence posture although, laparoscopic interventions spent most time in negligible-risk postures; 47.7% vs. 49.3%, compared to open procedures. Surgical consultants spent less time in suboptimal posture compared to fellow/registrars; 30.3% vs. 72.6% (Phase 1) and 33.8% vs. 65.3% (Phase 2).
Por que isso importa
Vibrational intervention from the device significantly decreased the time spent in suboptimal, high-risk postures. As procedure type wasn't correlated with postural changes, surgeon-specific factors in regulating posture are paramount. Finally, surgeon experience was positively correlated with improved surgical ergonomics.
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
Using wearable technology for Posture Regulation to Improve Surgical Ergonomics in the paediatric operating room: the UPRISE trial: a pilot study
Suvarna Soni, Angus M A Ritchie, Sue Liu, Maurizio Pacilli, Ramesh Mark Nataraja
Descritores MeSH
- Operating Rooms
- Ergonomics
- Posture
- Wearable Electronic Devices
- Humans
- Male
- Musculoskeletal Diseases
- Occupational Diseases
- Pilot Projects
- Prospective Studies
Veja também
Estudos relacionados
- Parâmetros ergonômicos baseados em evidências para uma prática cirúrgica mais segura: revisão sistemática
- Musculoskeletal Disorders in Surgeons: A Systematic Review on Prevalence, Risk Factors, and Mitigation Strategies
- Wearable sensors for classification of load-handling tasks with machine learning algorithms in occupational safety and health: a systematic literature review
- Biomechanical and ergonomic risks associated with cervical musculoskeletal dysfunction amongst surgeons: A systematic review
- Os pacientes se recuperam enquanto os cirurgiões sofrem: uma revisão narrativa sobre ergonomia cirúrgica na cirurgia laparoscópica