ScienceMed®
Imagem de arquivo, ilustrativa: Pastilha de um circuito integrado Ferranti F111-L ao microscópio

Using Virtual Reality to teach ultrasound-guided needling skills for regional anaesthesia: A randomised controlled trial

Cirurgia
Imagem de arquivo, ilustrativa — não é do estudo. Pastilha de um circuito integrado Ferranti F111-L ao microscópio. Revaldinho · CC BY 4.0 · Wikimedia Commons

Ensaio clínico randomizadoNível 2 · Nova evidênciaJournal of clinical anesthesia17 jun 202421 citações

Por ScienceMed · · a partir do resumo dos autores

Salvar

Resumo original em inglês

O que aconteceu

We previously designed and validated a virtual reality-based simulator to help train novices in ultrasound-guided needling skills necessary for safe and competent ultrasound-guided regional anaesthesia. This study was designed to compare the performance and error rates of novices trained by a human faculty aided with the assistance of this virtual reality simulator (virtual reality-assisted training), versus novices trained wholly by humans (conventional training).

In this single centre, randomised controlled study, we used a standardised teaching protocol, rigorous blinding, iterative training of assessors, and validated global rating scale and composite error score checklists to assess skills learning of novice participants.

O que encontraram

We recruited 45 novices and scored 270 assessments of performance and error rates. Inter-rater correlation coefficient of reliability of scoring between assessors for the global rating scale was 0.84 (95%CI 0.68-0.92) and for the composite error score checklist was 0.87 (95%CI 0.73-0.93). After adjustment for age, sex, Depression, Anxiety and Stress-21, and baseline score, there was no statistical difference for virtual reality-assisted training compared to conventional training in final global rating score (average treatment effect -3.30 (95%CI-13.07-6.48), p = 0.51) or in the final composite error score (average treatment effect 1.14 (95%CI -0.60-2.88), p = 0.20). Realism in the virtual reality simulator was similar to real-life when measured by the Presence Questionnaire, all components p > 0.79; and task workload assessed by the NASA-Task Load Index was not statistically different between groups, average treatment effect 5.02 (95%CI -3.51-13.54), p = 0.25. Results were achieved in the virtual reality-assisted group with half the human faculty involvement.

Por que isso importa

Novices trained using a hybrid, virtual reality-assisted teaching program showed no superiority to novices trained using a conventional teaching program, but with less burden on teaching resources.

Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.

O estudo original

Using Virtual Reality to teach ultrasound-guided needling skills for regional anaesthesia: A randomised controlled trial

Alwin Chuan, Anton Bogdanovych, Benjamin Moran, Supriya Chowdhury, Yean Chin Lim, Minh T Tran, Tsz Yui Lee, Jayden Duong, Jennifer Qian, Tung Bui et al.

Descritores MeSH

  • Anesthesia, Conduction
  • Virtual Reality
  • Ultrasonography, Interventional
  • Clinical Competence
  • Humans
  • Male
  • Needles
  • Reproducibility of Results
  • Simulation Training
  • Young Adult

Veja também

Estudos relacionados