Ensaio clínico randomizadoNível 2 · Nova evidênciaSurgical endoscopy20 ago 20251 citações

Por ScienceMed · · a partir do resumo dos autores

Salvar

Resumo original em inglês

O que aconteceu

The effects of traction direction in traction-assisted gastric endoscopic submucosal dissection (ESD) are underexplored. The clip-with-line (CWL) and spring-and-loop with clip (SLC) are unidirectional and direction-selectable traction devices, respectively. This study compared the procedure-related outcomes of CWL-assisted ESD (CWL-ESD) and SLC-assisted ESD (SLC-ESD) for superficial gastric neoplasms (SGNs).

This single-center randomized controlled trial included patients with SGNs who were randomly assigned to undergo CWL-ESD or SLC-ESD performed by an expert. The traction direction was classified as proximal, diagonally proximal, vertical, diagonally distal, or distal. Vertical traction (VT) was selected for SLC-ESD using the direction-selectable traction function. The primary endpoint was the median ESD time. The secondary endpoints included dissection speed. Multiple regression analysis was used to identify factors affecting ESD time.

O que encontraram

Overall, 105 patients who underwent SLC-ESD (n = 52) or CWL-ESD (n = 53) between August 2020 and April 2023 were included in the analysis. The median ESD time was significantly shorter in the SLC-ESD group than in the CWL-ESD group (26.0 vs. 40.5 min; P = 0.015). The median dissection speed was significantly faster in the SLC-ESD group than in the CWL-ESD group (24.9 vs. 18.2 mm2/min; P = 0.001). The traction direction significantly differed between the groups (P < 0.001), as VT was selected in all cases in the SLC-ESD group, compared with that in 11.3% of cases in the CWL-ESD group. Multiple regression analysis revealed that VT was independently associated with a shorter ESD time (P < 0.001). The complete resection rate did not differ between the groups (98.1% vs. 96.2%; P = 1.000). Adverse event rates were not different between the groups.

Por que isso importa

A direction-selectable traction device may be more effective than a unidirectional traction device in gastric ESD.

Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.

O estudo original

Unidirectional versus direction-selectable traction device in gastric endoscopic submucosal dissection: a randomized controlled trial

Mitsuru Nagata, Masayuki Namiki, Tomoaki Fujikawa, Hiromi Munakata

Descritores MeSH

  • Gastroscopy
  • Traction
  • Stomach Neoplasms
  • Endoscopic Mucosal Resection
  • Gastric Mucosa
  • Humans
  • Male
  • Middle Aged
  • Surgical Instruments
  • Treatment Outcome