ScienceMed®
Imagem de arquivo, ilustrativa: Músculo cardíaco em corte transversal, ao microscópio óptico

Ultrasound-guided vs. fluoro-guided axillary venous access for cardiac implantable electronic devices: a patient-based meta-analysis

Cardiologia
Imagem de arquivo, ilustrativa — não é do estudo. Músculo cardíaco em corte transversal, ao microscópio óptico. Berkshire Community College Bioscience Image Library · CC0 · Wikimedia Commons

MetanáliseNível 1 · Evidência consolidadaEuropace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology1 nov 20246 citações

Por ScienceMed · · a partir do resumo dos autores

Salvar

Resumo original em inglês

O que aconteceu

The use of ultrasound (US)-guided venous puncture for cardiac pacing/defibrillation lead placement may minimize the risk of periprocedural complications and radiation exposure. However, none of the published studies have been sufficiently powered to recommend this approach as the standard of care. We compare the safety and efficacy of ultrasound-guided axillary venous puncture (US-AVP) vs. fluoroscopy-guided access for cardiac implantable electronic devices (CIEDs) by performing an individual patient data meta-analysis based on previously published studies.

PROSPERO identifier: CRD42024539623.

O que encontraram

We conducted a thorough literature search encompassing longitudinal investigations (five randomized and one prospective studies) reporting data on X-ray-guided and US-AVP for CIED procedures. The primary endpoint was to compare the safety of the two techniques. Secondary endpoints included the success rate of each technique, the necessity of switching to alternative methods, the time needed to obtain venous access, X-ray exposure, and the occurrence of periprocedural complications. Six longitudinal eligible studies were identified including 700 patients (mean age 74.9 ± 12.1 years, 68.4% males). The two approaches for venous cannulation showed a similar success rate. The use of an X-ray-guided approach significantly increased the risk of inadvertent arterial punctures (OR: 2.15, 95% CI: 2.10-2.21, P = 0.003), after adjustment for potential confounders. Conversely, a US-AVP approach reduces time to vascular access, radiation exposure, and the number of attempts to vascular access.

Por que isso importa

The US-AVP enhances safety by reducing radiation exposure and time to vascular access while maintaining a low rate of major complications compared to the X-ray-guided approach.

Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.

O estudo original

Ultrasound-guided vs. fluoro-guided axillary venous access for cardiac implantable electronic devices: a patient-based meta-analysis

Francesco Vitali, Marco Zuin, Paul Charles, Javier Jiménez-Díaz, Seth H Sheldon, Ana Paula Tagliari, Federico Migliore, Michele Malagù, Mathieu Montoy, Felipe Higuera Sobrino et al.

Descritores MeSH

  • Axillary Vein
  • Defibrillators, Implantable
  • Ultrasonography, Interventional
  • Punctures
  • Female
  • Fluoroscopy
  • Humans
  • Male
  • Middle Aged
  • Pacemaker, Artificial