Três anos de seguimento dos resultados clínicos, radiográficos e relatados por pacientes para Zirconia e Implantes de Titânio na Região posterior: Um ensaio controlado randomizado
MedicinaResumo original em inglês
O que aconteceu
To compare the 3-year clinical, radiographic, esthetic, and patient-reported outcomes of zirconia (Zr) and titanium (Ti) implants placed in posterior sites in a randomized, controlled within-subject design.
Forty-two patients each received one Zr and one Ti implant. Clinical and radiographic outcomes were evaluated at baseline, 1, and 3 years after crown delivery. Marginal bone levels (MBL), peri-implant soft-tissue parameters, technical complications, esthetic outcomes (ΔE values, VAS scores), and patient-reported measures were assessed. Thirty-nine patients (37 Zr; 39 Ti implants) were available at 3 years.
The trial is registered in the German Clinical Trials Register (DRKS) under the ID DRKS00008591.
O que encontraram
The 3-year survival rate was 100% for Ti and 94.9% for Zr implants. MBL remained stable after the initial remodeling phase, with no clinically relevant differences between materials. Peri-implant soft-tissue conditions (BOP, plaque presence, PD, KT) were similar for Zr and Ti. Two zirconia implants were lost during the observation period. Peri-implantitis was diagnosed in 7.9% of the implants, affecting three titanium and three zirconia implants. Technical complications differed between groups: chipping occurred significantly more often at Zr implant-supported crowns. Ti implants showed two screw-loosening events, while Zr implants showed two cases of decementation. Esthetic and patient-reported outcomes were comparable, with low perceived mucosal color differences and a slight preference for Zr sites, if detectable.
Por que isso importa
Zr and Ti implants showed similar peri-implant health, marginal bone stability, esthetic outcomes, and patient satisfaction after 3 years. Zr implants, however, demonstrated a slightly lower survival rate and more chipping.
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
Three-Year Follow-Up of Clinical, Radiographic, and Patient-Reported Outcomes for Zirconia and Titanium Implants in the Posterior Region: A Randomized Controlled Trial
Anina Nives Zuercher, Ronald E. Jung, Stefan P. Bienz, Stephanie A Wenk, Daniel Stefan Thoma, Marc Balmer
Descritores MeSH
- Dental Implants
- Titanium
- Zirconium
- Dental Implantation, Endosseous
- Esthetics, Dental
- Female
- Follow-Up Studies
- Humans
- Male
- Middle Aged