The study assessed the clinical outcomes following treatment of peri-implant mucositis using Er:YAG laser or an ultrasonic device over six months. Patients' experience of pain, aesthetics, and Quality of life were further assessed.
One dental implant, per included patient, diagnosed with peri-implant mucositis underwent treatment with an Er:YAG laser (test) or an ultrasonic scaler (control) randomly. Treatments were performed at baseline and months three and six. At each session, oral hygiene was instructed after plaque registration, and the patient was guided in proper cleaning technique using a toothbrush and interproximal aids as needed. Full mouth bleeding on probing (FMBoP), full mouth plaque score (FMPS), implant bleeding on probing (BoP), implant mean graded bleeding (mBI), implant probing pocket depts (PPD), implant suppuration and bone levels were assessed. Oral health-related Quality of life (OHQoL) and visual analog scales (VAS), which reflect aesthetic satisfaction and pain of the treatment, were also evaluated.
Registered at www.
gov : study no, NCT05772299.
O que encontraram
Forty-six patients were included. FMBoP was significantly reduced from 30.1 to 21.5% (test) (p < 0.001) respectively from 35.0% to 30% (control) (p < 0.01). FMPS showed significant reduction from 61.5 to 32.7% (test) (p < 0.001) and from 58.7 to 39.1% (control) (p < 0.001). At the implant BoP reduced from 89.0 to 55.7% (test) (p < 0.001) respectively from 94.9 to 63.7% (control) (p < 0.001). mBI was reduced from 1.3 to 0.6 (test) (p < 0.01) and from 1.9 to 0.8 (control) (p < 0.001). Distribution of "no bleeding" increased from 13 to 61% (test) (p < 0.05) and from 0 to 35% (control) (p < 0.05). At month three, statistically significant intergroup differences were shown for PPD ≥ 4 mm with 43.5% (test) respectively 73.9% (control) (p < 0.05). At month six, statistically significant intergroup differences, were shown for FMBoP 21.5% (test) respectively 30% (control) (p < 0.05) and for plaque score at the implant 4.0% (test) respectively 26% (control) (p < 0.05). Less pain was reported in the laser group at three days 0.08 (test) respectively 0.2 (control) (p < 0.05).
Por que isso importa
Treatment of peri-implant mucositis was effective regardless of whether the treatment was performed with an Er:YAG laser or an ultrasonic scaler. Fewer diseased sites were diagnosed at six months following laser treatment.
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
Treatment of peri-implant mucositis using an Er:YAG laser or an ultrasonic device: a randomized, controlled clinical trial
Viveca Wallin Bengtsson, Akira Aoki, Koji Mizutani, Christel Lindahl, Stefan Renvert
Descritores MeSH
- Ultrasonic Therapy
- Dental Implants
- Stomatitis
- Lasers, Solid-State
- Peri-Implantitis
- Middle Aged
- Adult
- Treatment Outcome
- Quality of Life
- Aged
Estudos relacionados
- Treatment of peri-implant mucositis using an erythritol air-polishing or ultrasonic device: A randomized controlled trial
- Impact of Oral Hygiene Instructions in the Resolution of Peri-Implant Mucositis. A Randomized Controlled Trial
- Oral Hygiene Reinforcement With or Without Repeated Instrumentation in the Treatment of Peri-Implant Mucositis-A Randomised Controlled Trial
- Anti-infective therapy of peri-implant mucositis with adjunctive delivery of a sodium hypochlorite gel: a 6-month randomized triple-blind controlled clinical trial