ScienceMed®
Imagem de arquivo, ilustrativa: Artéria humana em corte transversal, ao microscópio óptico

Transcatheter aortic valve replacement outcomes in patients with high gradient versus low ejection fraction low gradient severe aortic stenosis: A meta-analysis of randomized controlled trials

Cardiologia
Imagem de arquivo, ilustrativa — não é do estudo. Artéria humana em corte transversal, ao microscópio óptico. Lord of Konrad · CC0 · Wikimedia Commons

MetanáliseNível 1 · Evidência consolidadaCardiovascular revascularization medicine : including molecular interventions27 jul 20240 citações

Por ScienceMed · · a partir do resumo dos autores

Salvar

Resumo original em inglês

O que aconteceu

The outcome of Low Flow-Low Gradient (LF-LG) severe aortic stenosis (AS) patients who underwent Transcatheter Aortic Valve Replacement (TAVR) procedure is not well defined. We conducted a systematic review of the literature to compare the outcomes of TAVR in LF-LG AS patients to the more traditional high gradient (HG) aortic stenosis.

We comprehensively searched for controlled randomized and non-randomized studies from 4 online databases. We are presenting the data using risk ratios (95 % confidence intervals) and measuring heterogeneity using Higgins' I2 index.

O que encontraram

Our analysis included 4380 patients with 3425 HG patients and 955 LF-LG patients from 6 cohort (5 retrospective and 1 prospective) studies. When compared to LFLG; TAVR was associated with significantly lower 30 days mortality in HG patients (5.1 % vs 7.4 %; relative risk [RR]: 0.55; 95 % confidence interval [CI]: 0.35 to 0.86; p < 0.01). Similar findings were also observed in 12-month cardiovascular (CV) mortality (5.5 % vs. 10.4 %; RR: 0.47; 95 % CI: 0.38 to 0.60; p < 0.01 and 12-month all-cause mortality (15.9 % vs 20.9 %; RR: 0.70; 95 % CI: 0.49 to 1.00; p < 0.05). There was no significant difference in myocardial infarction (MI) after TAVR between HG and LF-LG at 30 days (0.16 % vs. 0.95 %; p < 0.09) or 12 months (0.43 % vs. 0.95 %; p = 0.20). Similarly, there was no difference in stroke rates at 30 days (2.9 % vs. 2.86 %) or at 12 months (3.6 % vs. 3.06 %).

Por que isso importa

Patients with LF-LG severe AS who underwent TAVR had worse 1-year all-cause mortality, 30-day all-cause, and 1-year CV mortality when compared to TAVR in HG severe AS. There was no difference in MI or stroke rates. Therefore, with heart team discussion and informed patient decision regarding the risk and benefit, TAVR would still offer better outcomes in LFLG AS compared to conservative medical management.

Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.

O estudo original

Transcatheter aortic valve replacement outcomes in patients with high gradient versus low ejection fraction low gradient severe aortic stenosis: A meta-analysis of randomized controlled trials

Asseel Al-Bayati, Abdullah Alrifai, Fahed Darmoch, Haytham Alkhaimy, Zaher Fanari

Descritores MeSH

  • Aortic Valve
  • Aortic Valve Stenosis
  • Hemodynamics
  • Stroke Volume
  • Ventricular Function, Left
  • Transcatheter Aortic Valve Replacement
  • Risk Assessment
  • Time Factors
  • Randomized Controlled Trials as Topic
  • Recovery of Function