Trachway® flexible stylet facilitates the correct placement of double-lumen endobronchial tube: a prospective, randomized study
Anestesiologia e DorPor ScienceMed · · a partir do resumo dos autores
Resumo original em inglês
O que aconteceu
The mainstream facilitation of one-lung ventilation is using double-lumen endobronchial tubes. However, it is more difficult to be positioned properly and more likely to cause airway injuries. How to place double-lumen endobronchial tubes rapidly and correctly is important for thoracic anesthesiologists.
One hundred eight patients with an American Society of Anesthesiologists physical status of I to III were 20 years of age or over, and required one-lung ventilation for thoracic surgery. They were randomly assigned to the conventional technique group (n = 36), the flexible fiberoptic bronchoscopy group (n = 36), or the Trachway® flexible stylet group (n = 36). The primary endpoint was the time needed for intubation. T1, the time from the tip of the blade passing between the patient's lips to identification of the vocal cords; and T2, the time from identification of the vocal cords to the bronchial lumen was in the correct position.
ClinicalTrials.gov Identifier: NCT02364622, 18/02/2015, Retrospectively registered.
O que encontraram
T1 had no significant difference between groups, but T2 was significantly shorter in the Trachway® flexible stylet group (p < 0.0001) and longer in the conventional technique group (p < 0.0001).
Por que isso importa
Using Trachway® flexible stylet for correct placement of double-lumen endobronchial tubes not only significantly shortened the intubation time, but also reduced incidence of carinal injuries. It is an alternative, and a choice with good safety.
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
Trachway® flexible stylet facilitates the correct placement of double-lumen endobronchial tube: a prospective, randomized study
Hung-Te Hsu, Yi-Wei Kuo, Chao-Wei Ma, Miao-Pei Su, Kuang-Yi Tseng, Chin-Ling Li, Kuang-I Cheng
Descritores MeSH
- Intubation, Intratracheal
- One-Lung Ventilation
- Bronchi
- Bronchoscopy
- Humans
- Prospective Studies
Veja também
Estudos relacionados
- The efficacy and safety of extraluminal bronchial blockers in pediatric patients during one-lung ventilation for thoracoscopic surgery
- A novel technique of blindly positioning bronchial blockers for one-lung ventilation: a prospective, randomized, crossover study
- Robotic-assisted bronchoscopy for the diagnosis of peripheral pulmonary lesions: A systematic review and meta-analysis
- Choosing the correct-sized adult double-lumen tube: Quest for the holy grail