Three-dimensional Interlocking versus conventional miniplates for mandibular fractures fixation near the mental foramen: a split-mouth randomized clinical trial
NeurologiaPor ScienceMed · · a partir do resumo dos autores
Resumo original em inglês
O que aconteceu
To evaluate the 3D-Interlocking miniplate (3D-IMP) in the management of mandibular parasymphyseal fractures near the mental foramen (MF), and compare it clinically and radiographically with conventional miniplates (2MPs) in a split-mouth design
A total of 12 patients with recent bilateral mandibular fractures in the MF zone were treated with 3D-IMP on one side and with conventional 2MPs on the other side. Clinical evaluations were carried out for 6 postoperative weeks for the assessment of pain, Intra-fragmentary mobility, occlusion, wound healing complications, and an objective mental nerve neurosensory function. Radiographic assessment for the mean bone density was performed immediately after surgery and at 12 postoperative weeks
Trial was retrospectively registered at clinicaltrials.gov [ NCT06939010 /2025-4-22]
O que encontraram
By the end of the follow-up period, all cases reported a lack of intra-fragmentary mobility, proper occlusion, a significant reduction in pain intensity scores, and proper wound healing. Objective nerve testing reported a statistically significant improvement across the clinical follow-up period in both sides; however, one patient reported Level C sensation in the 2MPs side (4.17%) at the 6th postoperative week. Both sides showed a significant increase in mean bone density at 12 weeks ( P < 0.001 * ), with the 3D-IMP side demonstrating a significantly higher bone density (1107.4 ± 142.2 HU) than the 2MPs side (960.9 ± 97.58 HU)
Por que isso importa
3D Interlocking miniplates proved to be an effective alternative to conventional miniplates for mandibular parasymphyseal fractures near the MF, offering enhanced bone healing and better neurosensory outcomes
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
Three-dimensional Interlocking versus conventional miniplates for mandibular fractures fixation near the mental foramen: a split-mouth randomized clinical trial
Ibrahim Mohamed Abdelhamed, Ahmed Ossama Sweedan, Reem M Ismail, Yehia El-Mahallawy
Descritores MeSH
- Bone Plates
- Fracture Fixation, Internal
- Mandibular Fractures
- Male
- Middle Aged
- Bone Density
- Adult
- Treatment Outcome
- Female
- Humans
Veja também
Estudos relacionados
- Placa tridimensional de titânio versus fixação convencional de duas miniplacas para fraturas de ângulo mandibular: ensaio clínico randomizado
- Customized z-shaped versus conventional miniplates for fixation of parasymphyseal/body mandibular fractures: a randomized controlled trial evaluating clinical and radiographic outcomes
- Digital technology revolutionizing mandibular fracture treatment: a comparative analysis of patient-specific plates and conventional titanium plates
- Miniplacas tridimensionais versus convencionais no manejo de fraturas de ângulo mandibular: revisão sistemática e metanálise