The impact of a commercial lower extremity exoskeleton on metabolic load, perceived exertion, and physiological response to a challenging military relevant task: A randomized cross-over design pilot study

Medicina

Ensaio clínico randomizadoNível 2 · Nova evidênciaPloS one24 jan 20253 citações

Por ScienceMed · · a partir do resumo dos autores

Salvar

Resumo original em inglês

O que aconteceu

To assess physiological metrics during the use of a commercially available bilateral active ankle exoskeleton during a challenging military-relevant task and if use of the exoskeleton during this task influences: metabolic load, physiological measures or rate of perceived exertion.

Nine healthy volunteers (5M, 4F) completed this randomized cross-over design trial, with a baseline visit and two randomized test sessions (with/without the exoskeleton). Variables included impact on time to exhaustion during walking on a treadmill at varying speeds and gradients (0-15%) at 26.7°C, 50% humidity with a loaded rucksack (30% body weight). The primary outcome measure was change in metabolic cost with/without the exoskeleton (O2 consumption, metabolic equivalents); secondary outcomes were change in heart rate and perceived exertion between conditions.

O que encontraram

Participants averaged 22.4 ± 4.5 years old, 173.7 ± 7.4 cm tall, weighed 80.9 ± 13.9 kg, and VO2max of 43.8 ± 10.6 mL/kg/min. Total kcals did not differ between conditions (with/without exoskeleton; t = 0.98; p = 0.357). Kcals/min were significantly lower (1.06 kcals/min) with the exoskeleton (t = 3.94; p = 0.004). Average oxygen consumption (VO2) was significantly lower (2.36 mL/kg/min) with the exoskeleton (t = 2.81; p = 0.023), and peak VO2 was 3.33 mL/kg/min lower with the exoskeleton (t = 2.37; p = 0.045). Peak and Average METS were also lower with the exoskeleton by 0.98 (t = 2.61; p = 0.031) and 1.23 (t = 2.39; p = 0.044) respectively.

Por que isso importa

Results suggest a powered ankle exoskeleton may decrease energy consumption during military relevant tasks when conducted in a laboratory environment. There may also be physiological benefits such as reduced core temperate and heart rate. Replication of this work in the field environment is warranted.

Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.

O estudo original

The impact of a commercial lower extremity exoskeleton on metabolic load, perceived exertion, and physiological response to a challenging military relevant task: A randomized cross-over design pilot study