ScienceMed®
Imagem de arquivo, ilustrativa: Músculo cardíaco em corte longitudinal, com os discos intercalares, ao microscópio óptico

The effect of smart glasses combined with ultrasound on radial arterial catheterization: a randomized controlled trial

Pneumologia
Imagem de arquivo, ilustrativa — não é do estudo. Músculo cardíaco em corte longitudinal, com os discos intercalares, ao microscópio óptico. Berkshire Community College Bioscience Image Library · CC0 · Wikimedia Commons

Ensaio clínico randomizadoNível 2 · Nova evidênciaBMC anesthesiology29 nov 202413 citações

Por ScienceMed · · a partir do resumo dos autores

Salvar

Resumo original em inglês

O que aconteceu

The integration of smart glasses with ultrasound technology offers a novel approach to improve the efficiency of radial arterial catheterization. Few studies have investigated the effectiveness of smart glasses in enhancing procedural outcomes in a clinical setting. This study aims to assess whether smart glasses combined with ultrasound can improve the initial success rate of radial artery catheterization compared to traditional ultrasound-guided methods in adults.

This single-blinded, randomized controlled trial enrolled patients aged 18-70 with American Society of Anesthesiologists physical status I-III, who required radial artery catheterization as part of their procedure under general anesthesia. Patients were randomized 1:1 into the ultrasound group and the smart glasses group. Radial arterial catheterization was carried out by one of six anesthesiologists before general anesthesia. The primary endpoint was the first puncture success rate. Secondary endpoints included hand-eye coordination (measured by head rotations, probe repositioning and needle redirections), operator's satisfaction.

The study was registered at Chictr.org.cn with the number ChiCTR2400081399 on 29/02/2024.

O que encontraram

A total of 222 patients were analyzed, with the smart glasses group demonstrating a higher rate of first puncture success compared to the control group (88.3% [98/111] vs. 72.1% [80/111]; P = 0.002; relative risk [RR], 1.23; 95% CI (1.07, 1.40)). Hand-eye coordination improved significantly in the smart glasses group than the control group, including: fewer number of head rotations (0 [0, 0] vs. 3 [2, 6]; P < 0.001); fewer number of ultrasound probe repositioning (0 [0, 0] vs. 0 [0, 1]; P < 0.001); fewer number of needle redirections (0 [0, 1] vs. 1 [0, 3]; P < 0.001). The proportion of positive satisfaction (81 to 100 points) in the smart glasses group was higher (89.2% [99/111] vs. 69.4% [77/111]; P < 0.001; RR, 1.29; 95% CI (1.12, 1.48)).

Por que isso importa

The use of smart glasses significantly improved the first puncture success rate, hand-eye coordination ability and operators' satisfaction in radial arterial catheterization.

Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.

O estudo original

The effect of smart glasses combined with ultrasound on radial arterial catheterization: a randomized controlled trial

Yan Wang, Mingjing Chen, Ting Zou, Yan Weng, Wenjie Mao, Qing Zhong, Haibo Song

Descritores MeSH

  • Catheterization, Peripheral
  • Radial Artery
  • Ultrasonography, Interventional
  • Smart Glasses
  • Anesthesia, General
  • Female
  • Humans
  • Male
  • Middle Aged
  • Single-Blind Method

Veja também

Estudos relacionados