ScienceMed®
Imagem de arquivo, ilustrativa: Músculo cardíaco em corte transversal, ao microscópio óptico

The effect of cardiac resynchronization without a defibrillator on morbidity and mortality: an individual patient data meta-analysis of COMPANION and CARE-HF

Cardiologia
Imagem de arquivo, ilustrativa — não é do estudo. Músculo cardíaco em corte transversal, ao microscópio óptico. Berkshire Community College Bioscience Image Library · CC0 · Wikimedia Commons

MetanáliseNível 1 · Evidência consolidadaEuropean journal of heart failure22 mai 202238 citações

Por ScienceMed · · a partir do resumo dos autores

Salvar

Resumo original em inglês

O que aconteceu

Cardiac resynchronization therapy (CRT) reduces morbidity and mortality for patients with heart failure, reduced left ventricular ejection fraction, QRS duration >130 ms and in sinus rhythm. The aim of this study was to identify patient characteristics that predict the effect, specifically, of CRT pacemakers (CRT-P) on all-cause mortality or the composite of hospitalization for heart failure or all-cause mortality.

COMPANION, NCT00180258; CARE-HF, NCT00170300.

O que encontraram

We conducted an individual patient data meta-analysis of the Comparison of Medical Therapy, Pacing, and Defibrillation in Heart Failure (COMPANION) and Cardiac Resynchronization-Heart Failure (CARE-HF) trials. Only patients assigned to CRT-P or control (n = 1738) were included in order to avoid confounding from concomitant defibrillator therapy. The influence of baseline characteristics on treatment effects was investigated. Median age was 67 (59-73) years, most patients were men (70%), 68% had a QRS duration of 150-199 ms and 80% had left bundle branch block. Patients assigned to CRT-P had lower rates for all-cause mortality (hazard ratio [HR] 0.68, 95% confidence interval [CI] 0.56-0.81; p < 0.0001) and the composite outcome (HR 0.67, 95% CI 0.58-0.78; p < 0.0001). No pre-specified characteristic, including sex, aetiology of ventricular dysfunction, QRS duration (within the studied range) or morphology or PR interval significantly influenced the effect of CRT-P on all-cause mortality or the composite outcome. However, CRT-P had a greater effect on the composite outcome for patients with lower body surface area and those prescribed beta-blockers.

Por que isso importa

Cardiac resynchronization therapy-pacemaker reduces morbidity and mortality in appropriately selected patients with heart failure. Benefits may be greater in smaller patients and in those receiving beta-blockers. Neither QRS duration nor morphology independently predicted the benefit of CRT-P.

Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.

O estudo original

The effect of cardiac resynchronization without a defibrillator on morbidity and mortality: an individual patient data meta-analysis of COMPANION and CARE-HF

John G F Cleland, Michael R Bristow, Nicholas Freemantle, Brian Olshansky, Daniel Gras, Leslie Saxon, Luigi Tavazzi, John Boehmer, Stefano Ghio, Arthur M Feldman et al.

Descritores MeSH

  • Defibrillators, Implantable
  • Heart Failure
  • Cardiac Resynchronization Therapy
  • Humans
  • Male
  • Adrenergic beta-Antagonists
  • Stroke Volume
  • Ventricular Function, Left
  • Treatment Outcome
  • Defibrillators

Veja também

Estudos relacionados