The comparison of albumin and 6% hydroxyethyl starches (130/0.4) in cardiac surgery: a meta-analysis of randomized controlled clinical trials
Emergência e Terapia IntensivaPor ScienceMed · · a partir do resumo dos autores
Resumo original em inglês
O que aconteceu
Fluid administration is a key tool in the maintenance of normovolemia in patients with cardiac surgery. The trials that evaluated the safety of 6% hydroxyethyl starch (HES) 130/0.4 in cardiac surgical patients were inconsistent. It is necessary to compare the efficacy and safety of albumin and 6% HES (130/0.4).
We searched for the randomized controlled clinical trials that compared human albumin with 6% HES (130/0.4) in cardiac surgery in PubMed, Cochrane, and Embase.
O que encontraram
Ten studies involved a total of 1567 patients were included in our meta-analysis. For the efficiency, there was no difference in total volume of infusion between compared groups [P = 0.64, Fixed Effect Model (FEM): standardized mean difference (SMD) = 0.04, 95% confidence interval (CI) (- 0.12, 0.20)]. As for safety, the albumin show more risk than hydroxyethyl starch 130/0.4 in blood loss [P = 0.02, FEM: SMD: 0.22, 95% CI (0.03, 0.41)]. There was no difference in the frequency of transfusions (P = 0.20, RR = 1.11; 95% CI (0.95, 1.27)) between the two groups. No difference was observed for the days in intensive care unit [P = 0.05, FEM: SMD = - 0.18, 95% CI (- 0.36, 0.00)], and the days in hospital [P = 0.32, FEM: SMD = - 0.11, 95% CI (- 0.32, 0.10)]. Furthermore, both the incidence of AKI, RRT, and mortality were comparable in the two groups.
Por que isso importa
This study provided evidence that the 6% HES (130/0.4) might be the substitute for HA, which reduced the economic burden for patients with cardiac surgery. However, the effect of 6% HES (130/0.4) and HA on AKI still needs to be further studied.
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
The comparison of albumin and 6% hydroxyethyl starches (130/0.4) in cardiac surgery: a meta-analysis of randomized controlled clinical trials
Ling Wei, Dongping Li, Lin Sun
Descritores MeSH
- Cardiac Surgical Procedures
- Plasma Substitutes
- Albumins
- Fluid Therapy
- Humans
- Hydroxyethyl Starch Derivatives
Veja também
Estudos relacionados
- Human albumin and 6% hydroxyethyl starches (130/0.4) in cardiac surgery: a meta-analysis revisited
- Effect of 6% Hydroxyethyl Starch 130/0.4 on Inflammatory Response and Pulmonary Function in Patients Having Cardiac Surgery: A Randomized Clinical Trial
- Open randomized trial of the effects of 6% hydroxyethyl starch 130/0.4/9 and 5% albumin on safety profile, volume efficacy, and glycocalyx degradation in hepatic and pancreatic surgery
- Albumina perioperatória versus outros fluidos para prevenir lesão renal associada à cirurgia cardíaca: revisão sistemática e metanálise de ensaios randomizados