ScienceMed®
Imagem de arquivo, ilustrativa: Osso compacto humano em corte transversal, ao microscópio óptico

Systematic review of humeral shaft fracture (OTA/AO 12) complicated with iatrogenic radial nerve injury

Ortopedia
Imagem de arquivo, ilustrativa — não é do estudo. Osso compacto humano em corte transversal, ao microscópio óptico. Berkshire Community College Bioscience Image Library · CC0 · Wikimedia Commons

Revisão sistemáticaNível 1 · Evidência consolidadaEuropean journal of medical research25 jul 202410 citações

Por ScienceMed · · a partir do resumo dos autores

Salvar

Resumo original em inglês

O que aconteceu

To compare the iatrogenic radial nerve injury (iRNI) rate of different implant (plate vs. intramedullary nail) and surgical approaches during humeral shaft fracture surgery.

The online PubMed database was used to search for articles describing iRNI after humeral fracture with a publication date from Jan 2000 to October 2023. The following types of articles were selected: (1) case series associating with adult humeral shaft fracture, preoperative radial nerve continuity, non-pathological fracture and non-periprosthetic fracture; (2) involving humeral shaft (OTA/AO 12) fractures. Articles where we were unable to judge surgical approach or fracture pattern (OTA/AO 12) were excluded. The data were analyzed by SPSS 27.0 and Chi-square test was performed to identify incidence of iRNI associated with different implant and surgical approaches.

Level IV.

O que encontraram

Fifty-four articles with 5063 cases were included, with 3510 cases of the plate, 830 cases of intramedullary nail and 723 cases of uncertain internal fixation. The incidences of iRNI with plate and intramedullary nail were 5.95% (209/3510) and 2.77% (23/830) (p 0.05). The iRNI rates were 2.87% (21/732) for anterograde intramedullary nail and 2.04% (2/98) for retrograde intramedullary nail (p > 0.05). In humeral bone nonunion surgery, the rate of iRNI was 15.00% (9/60) for anterolateral approach, 16.7% (2/12) for lateral approach and 18.2% (6/33) for posterior approach (p > 0.05).

Por que isso importa

Intramedullary nailing is the preferred method of internal fixation for humeral shaft fractures that has the lowest rate of iRNI. Compared with anterolateral and posterior approaches, the lateral surgical approach had a higher incidence of iRNI. The rate of iRNI in MIPO was lower than that in open reduction and internal fixation.

Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.

O estudo original

Systematic review of humeral shaft fracture (OTA/AO 12) complicated with iatrogenic radial nerve injury

Zeyu Zhang, Zhongpei Lin, Qinglin Qiu, Xincai Xiao, Shouwen Su, Xiaoyue Wen, Bo He

Descritores MeSH

  • Humeral Fractures
  • Iatrogenic Disease
  • Radial Nerve
  • Fracture Fixation, Intramedullary
  • Bone Nails
  • Incidence
  • Bone Plates
  • Fracture Fixation, Internal
  • Humans

Veja também

Estudos relacionados