ScienceMed®
Imagem de arquivo, ilustrativa: Radiografia de um quadril normal: a cabeça do fêmur encaixada no acetábulo

Staples versus sutures for skin closure in hip arthroplasty: a meta-analysis and systematic review

Cirurgia
Imagem de arquivo, ilustrativa — não é do estudo. Radiografia de um quadril normal: a cabeça do fêmur encaixada no acetábulo. Mikael Häggström · CC0 · Wikimedia Commons

MetanáliseNível 1 · Evidência consolidadaJournal of orthopaedic surgery and research24 dez 202119 citações

Por ScienceMed · · a partir do resumo dos autores

Salvar

Resumo original em inglês

O que aconteceu

The purpose of the present study was to estimate complications and other outcomes associated with staple and suture closure after hip arthroplasty through meta-analysis techniques and a systematic review.

We searched for articles in EMBASE, PubMed, Medline, Web of Science and the Cochrane Library. To determine the eligibility of the searched trials, Cochrane Collaboration's Review Manager software was used to perform the meta-analysis.

O que encontraram

Five randomized controlled trials and one retrospective cohort trial were included in our study. Our study indicated that for skin closure after hip arthroplasty, the risks of superficial infection and prolonged discharge were higher with staples than with sutures. There was no significant difference between the two groups in terms of allergic reaction, dehiscence, inflammation, abscess formation, the Hollander Wound Evaluation Scale or patient's satisfaction with skin closure methods. However, suturing required a longer operating time.

Por que isso importa

Closure with sutures is associated with lower risks of superficial infection and prolonged discharge than closure with staples following hip arthroplasty, but it may take more time.

Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.

O estudo original

Staples versus sutures for skin closure in hip arthroplasty: a meta-analysis and systematic review

Zirui Liu, Binfeng Liu, Hao Yang, Liang Zhao

Descritores MeSH

  • Arthroplasty, Replacement, Hip
  • Wound Healing
  • Surgical Stapling
  • Orthopedic Procedures
  • Sutures
  • Surgical Wound Infection
  • Suture Techniques
  • Humans

Veja também

Estudos relacionados