
Similar outcome with a new anteverted or a straight standard stem: a randomized study of 72 total hip arthroplasties evaluated with clinical variables, radiostereometry, and DXA up to 2 years
CirurgiaPor ScienceMed · · a partir do resumo dos autores
Resumo original em inglês
O que aconteceu
Background and purpose - The anatomical uncemented stem, SP-CL (Static Physiologicus - CementLess), designed to facilitate insertion and to avoid stress concentration at solitary contact points, has been on the market since 2014 but is not well documented. We studied its clinical performance, migration, and associated bone remodeling in a randomized controlled trial, with the Corail stem as control. Patients and methods - 79 patients (80 hips) were primarily recruited and 71 patients (72 hips, 36 SP-CL, 36 Corail) attended the last follow-up at 2 years. The Oxford Hip Score (OHS) was the primary outcome. In addition, we assessed stem migration, changes in bone mineral density, and development of radiolucencies by RSA, DXA, and conventional radiography. Results - At 2 years Oxford Hip Score was similar between the SP-CL and Corail stem. At 2 years the SP-CL stems showed a median distal migration of 0.23 mm (-0.1 to 5.2) and the Corail stems of 0.11 mm (-0.4 to 4.4). The SP-CL stems showed slightly more loss of bone mineral density in Gruen region 7 (p = 0.003). Interpretation - We found no difference in clinical results between the SP-CL and the well-documented Corail stem. The same stem stability was reached between 1 and 2 years postoperatively for both stems. As a next step we think that the SP-CL stem should be studied in a multi-center setting, before being accepted for general use.
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
Similar outcome with a new anteverted or a straight standard stem: a randomized study of 72 total hip arthroplasties evaluated with clinical variables, radiostereometry, and DXA up to 2 years
Karin Rilby, Maziar Mohaddes, Emma Nauclér, Johan Kärrholm
Descritores MeSH
- Hip Prosthesis
- Prosthesis Design
- Arthroplasty, Replacement, Hip
- Foreign-Body Migration
- Male
- Middle Aged
- Pain Measurement
- Absorptiometry, Photon
- Bone Density
- Bone Remodeling
Veja também
Estudos relacionados
- Stem migration and bone density at ten years : a randomized radiostereometry and dual-energy X-ray absorptiometry study on a short uncemented hip stem with and without a collar
- Similar femoral stem fixation but less metaphyseal loss of bone mineral density with a taper-wedge design and diaphyseal bone preservation with a long and round-tapered design: a 5-year randomized RSA and DXA study of 50 patients
- Evaluation of Proximal Femoral Bone Mineral Density in Cementless Total Hip Arthroplasty: A 3-Arm Prospective Randomized Controlled Trial
- Migration patterns of uncemented femoral stems in hip replacement: a systematic review and meta-analysis of clinical radiostereometric analysis cohort studies