ScienceMed®
Imagem de arquivo, ilustrativa: Radiografia histórica dos dois joelhos

Resultados funcionais da instrumentação específica do paciente versus instrumentação convencional para substituição unicompartimental do joelho: revisão sistemática e metanálise

Ortopedia
Imagem de arquivo, ilustrativa — não é do estudo. Radiografia histórica dos dois joelhos. Wellcome Collection · CC BY 4.0 · Wikimedia Commons

MetanáliseNível 1 · Evidência consolidadaThe Knee25 ago 20260 citações

Por ScienceMed · · · a partir do resumo dos autores

Salvar

Resumo original em inglês

O que aconteceu

Patient-specific instrumentation (PSI) has been introduced in unicompartmental knee arthroplasty (UKA) to improve implant positioning and potentially post-operative function. However, its clinical advantage over conventional instrumentation (cUKA) remains uncertain. This study aimed to evaluate current evidence comparing functional outcomes and implant survival following UKA performed with PSI versus conventional instrumentation.

A systematic review and meta-analysis was conducted in accordance with PRISMA guidelines. Embase, MEDLINE and the Cochrane Library were searched for studies comparing PSI and cUKA in primary UKA. The primary outcomes were 1-year Oxford Knee Score (OKS) and change in OKS from preoperative to post-operative assessment. Secondary outcomes included Knee Society Score (KSS), Knee injury and Osteoarthritis Outcome Score (KOOS), WOMAC and revision rates. Risk of bias was assessed using RoB 2 and ROBINS-I.

O que encontraram

Fourteen studies including 1680 knees in 1670 patients were included: five randomised controlled trials and nine retrospective comparative studies. All randomised studies had low overall risk of bias, while several non-randomised studies had moderate or high risk. No significant difference was found between PSI and conventional UKA for 1-year post-operative OKS (mean difference 0.90, 95% confidence interval -2.65 to 4.45; I2 = 0%). KSS and KOOS outcomes at 3 months and at ≥12 months also showed no significant between-group differences. WOMAC data were insufficient for meta-analysis. Revision data was heterogeneous and unsuitable for pooling.

Por que isso importa

PSI does not demonstrate superior post-operative functional outcomes compared with conventional instrumentation in UKA. Its effect on revision risk remains uncertain owing to limited and heterogeneous evidence.

Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.

O estudo original

Functional outcomes of patient-specific instrumentation versus conventional instrumentation for unicompartmental knee replacement: A systematic review and meta-analysis

Valentin Ruhle, Branavan Rudran, Brook Leung, Christian Merle, David Murray, Andrew Price, Abtin Alvand

Descritores MeSH

  • Arthroplasty, Replacement, Knee
  • Knee Prosthesis
  • Osteoarthritis, Knee
  • Humans
  • Recovery of Function
  • Treatment Outcome
  • Prosthesis Design
  • Reoperation

Veja também

Estudos relacionados