ScienceMed®
Imagem de arquivo, ilustrativa: Radiografia histórica do joelho de um menino (1896)

Restoring tibial obliquity for kinematic alignment in total knee arthroplasty: conventional versus patient-specific instrumentation

Ortopedia
Imagem de arquivo, ilustrativa — não é do estudo. Radiografia histórica do joelho de um menino (1896). Wellcome Collection · CC BY 4.0 · Wikimedia Commons

Ensaio clínico randomizadoNível 2 · Nova evidênciaArchives of orthopaedic and trauma surgery20 mar 20235 citações

Por ScienceMed · · a partir do resumo dos autores

Salvar

Resumo original em inglês

O que aconteceu

In total knee arthroplasty (TKA), tibial obliquity-restoration using kinematic alignment (KA) poses a major difference to conventional mechanical alignment. This study aimed at analysing the accuracy of conventional instrumentation (CI) versus patient-specific instrumentation (PSI) to restore anatomic tibial obliquity measured by the medial proximal tibial angle (MPTA) on conventional X-rays.

One-hundred patients were randomized to receive CI (n = 50) or PSI (n = 50) for TKA. Further 100 patients received CI without randomisation, resulting in 200 patients in total (127 women, mean age: 70.7 (range: 48-90 years). Pre- and postoperative X-rays were measured twice by two observers with a 2-week break in-between. Inter- and intraclass correlations were calculated and postoperative tibial obliquity compared to preoperative anatomy.

O que encontraram

In 150 patients with CI, no case with tibial obliquity-deviation greater than 2° was found, whilst 21.3% (n = 32) and 0.7% (n = 1) of cases and had a deviation of 0°-1°, and 1°-2°, respectively. In the remaining 78.0% (n = 117), tibial obliquity was restored. In 50 patients with PSI, no single case with a deviation greater than 1° was found. Sixty percent (n = 30) had a deviation of 0°-1°. In the remaining 40.0% (n = 20), no deviation from preoperative measurements was found. Consequently, CI resulted in a significantly smaller change in tibial obliquity from preoperative to postoperative than PSI (p 0.90).

Por que isso importa

Both conventional and patient-specific instrumentation revealed adequate results with respect to restoring tibial obliquity in kinematically aligned TKA, with conventional instrumentation achieving superior results.

Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.

O estudo original

Restoring tibial obliquity for kinematic alignment in total knee arthroplasty: conventional versus patient-specific instrumentation

Maria Anna Smolle, Amir Koutp, Clemens Clar, Lukas Leitner, Andreas Leithner, Patrick Sadoghi

Descritores MeSH

  • Osteoarthritis, Knee
  • Knee Prosthesis
  • Arthroplasty, Replacement, Knee
  • Humans
  • Knee Joint
  • Aged
  • Radiography
  • Tibia
  • Biomechanical Phenomena
  • Female

Veja também