Recommendations for selection of target parameters and process recommendations for audiological and technical functional testing of cochlear implant : Prepared by the ERA consortium (AG-ERA) of ADANO in cooperation with the Implantable Hearing Systems expert committee of the DGA. Confirmed by the board of ADANO on 31.01.2025. German version
NeurologiaResumo original em inglês
O que aconteceu
Continuous monitoring of the technical and physiological function of cochlear implants (CI) is a central part of the care process. Despite worldwide efforts to standardise procedures, there is still considerable variation between CI centres, particularly in terms of the methods used, their practical implementation and the definition of meaningful target parameters. A standardised structured test procedure is needed for reliable quality assurance and better comparability. Against this background, the ADANO Working Group for Evoked Response Audiometry (AG-ERA), in close cooperation with the Cochlear Implants and Implantable Hearing Systems Committee of the German Society of Audiology (DGA), developed a minimum standard for audiological and technical functional testing of CIs in an open consensus process. This standard defines basic requirements for performance and documentation and serves as a practical recommendation for CI centres. It is intended to improve interdisciplinary cooperation, increase the quality of care and enable structured long-term optimised care for CI patients.
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
Recommendations for selection of target parameters and process recommendations for audiological and technical functional testing of cochlear implant : Prepared by the ERA consortium (AG-ERA) of ADANO in cooperation with the Implantable Hearing Systems expert committee of the DGA. Confirmed by the board of ADANO on 31.01.2025. German version
Alexander Müller, M Blümer, O C Dziemba, A Elsholz, L Fröhlich, U Hoppe, D Polterauer, T Rahne, T Steffens, M Walger et al.
Descritores MeSH
- Audiology
- Audiometry, Evoked Response
- Cochlear Implants
- Cochlear Implantation
- Germany
- Humans
Veja também
Estudos relacionados
- Intraoperative Intracochlear Electrocochleography and Hearing Preservation Early after Cochlear Implantation: A Meta-Analysis
- Bridging the gap: A systematic review of intraoperative electrocochleography during cochlear implantation and preservation of residual hearing
- Comprehensive literature review on the application of the otological-surgical planning software OTOPLAN® for cochlear implantation. German version
- Electrocochleography and Cochlear Implantation: A Systematic Review