Radiation Quality and Workflow in NRG GY017: Anti-PD-L1 (Atezolizumab) as an Immune Primer or Concurrently With Radiation Therapy for Node-Positive Locally Advanced Cervical Cancer
Ginecologia e ObstetríciaPor ScienceMed · · a partir do resumo dos autores
Resumo original em inglês
O que aconteceu
Advances in radiation (RT) treatment planning enhance the need for uniform quality oversight on clinical trials. NRG GY-017 was a randomized trial of the anti-program ligand death 1 (PD-L1) antibody, atezolizumab, before and concurrent (arm A) or concurrent with chemoradiaton (arm B) for locally advanced cervical cancer. We describe the prospectively collected pretreatment RT quality and workflow.
Forty patients were consented and randomized. Thirty-seven patients submitted pretreatment RT plans for central review, and 36 patients ultimately received protocol therapy. Intensity modulated radiation therapy (IMRT) contouring guidelines and dose specifics were outlined in the protocol, with volume and dose deviations specified as per protocol, minor and major variation. Each site had to pass a standardized IMRT credentialing process. Sites were required to submit an IMRT plan for physician expert contour target and organ-at-risk review in a rapid pretreatment manner. An expert physician then scored the contours and plan as per protocol or as a deviation. For major deviations, the sites were required to revise and resubmit the plans, which were then re-reviewed prior to protocol start.
O que encontraram
The median follow-up time was 20 months. Thirty-seven participants had a central expert review of the pretreatment external beam radiation therapy plan. Thirteen plans (35%) were scored as a major deviation requiring revision: 11 secondary to contours (5 bowel and 6 nodal volumes) and 2 secondary to incorrect expansion on the volume or the dose distribution. The major deviation plans were resubmitted; however, 2 of them required revisions for a total of 3 plans. Because of the quality review, all patients had per-protocol scores prior to the treatment administration.
Por que isso importa
Our data indicate that 35% of the baseline submitted advanced technology IMRT plans required revision and resubmission in order to meet protocol standards. RT plan quality workflow continues to evolve with advanced techniques and has implications in clinical trial review. Pretreatment plan review is an important quality measure for cervical cancer clinical trials.
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
Radiation Quality and Workflow in NRG GY017: Anti-PD-L1 (Atezolizumab) as an Immune Primer or Concurrently With Radiation Therapy for Node-Positive Locally Advanced Cervical Cancer
Jyoti Mayadev, Wei Deng, Hayeon Kim, Ying Xiao, Junzo P Chino, Mitchell R Kamrava, Jessica Leif, Sharad Ghamande, Dominque Rash, Laura L Holman et al.
Descritores MeSH
- Uterine Cervical Neoplasms
- Radiotherapy, Intensity-Modulated
- Workflow
- Chemoradiotherapy
- Antibodies, Monoclonal, Humanized
- Radiotherapy Planning, Computer-Assisted
- Organs at Risk
- Female
- Humans
- Prospective Studies
Veja também
Estudos relacionados
- Mono iso-centric VMAT planning for SBRT of multiple liver metastasis- A case report
- Pelvic bone marrow sparing radiotherapy for cervical cancer: A systematic review and meta-analysis
- Image guided brachytherapy quality assurance on NRG GY017 investigating immunotherapy in addition to chemoradiation for locally advanced cervical cancer
- Single-photon emission computed tomography-defined active bone marrow-sparing volumetric-modulated arc therapy reduces the incidence of acute hematologic toxicity in locally advanced cervical cancer patients who receive chemoradiotherapy: A single-center prospective randomized controlled trial