Prediction of non-responders to oral appliance treatment of obstructive sleep apnea: a pilot study

Neurologia
Imagem de arquivo, ilustrativa — não é do estudo. Radiografia de tórax de pulmões saudáveis. N.a. Radiology by Dr. Johan Verbeken. Scan and image editing by Vincent Mia Edie Verheyen · domínio público · Wikimedia Commons

Ensaio clínico randomizadoNível 2 · Nova evidênciaSleep & breathing = Schlaf & Atmung15 abr 20252 citações

Por ScienceMed · · a partir do resumo dos autores

Salvar

Resumo original em inglês

O que aconteceu

Several clinically available variables have been identified as predictors of non-response to oral appliance (OA) treatment, including endotypical traits such as severe upper airway collapsibility, unstable ventilatory control, and low arousal threshold. This study aimed to identify potential predictors of non-response to OA treatment in patients with OSA non-adherent to treatment with positive airway pressure.

Patients in this study were initially treated with OAs with and without elastic bands in a crossover design. Subsequently, each patient selected their preferred treatment modality for continued therapy based on subjective preferences. The chosen OA treatment. The chosen OA treatment modality was titrated optimally based on reduction of REI. Patients not reaching > 50% reduction of REI from baseline were classified as non-responders. Statistical analyses were conducted using Student's t-test and Pearson's chi-squared test to assess differences in baseline variables between responders and non-responders, and logistic regression analyses were performed to investigate variables associated with not responding to OA treatment.

NCT05987618 (clinicaltrials.gov).

O que encontraram

Overall, 63.2% (n = 36) of the patients were responders to OA treatment following titration. Smaller distance from habitual bite position to maximal retruded position (Odds ratio: 0.28, p = 0.016), positional OSA (Odds ratio: 0.94, p = 0.024) and a higher number of the endotypical OSA traits severe collapsibility, high loop gain and low arousal threshold (Odds ratio: 7.41, p = 0.038), were found to predict non-response to OA treatment.

Por que isso importa

These novel findings suggest that severe upper airway collapsibility, high loop gain and low arousal threshold, identified through clinically available variables, appear to be important predictors of non-response to OA treatment, along with short distance from habitual bite position to maximal retruded position and positional OSA.

Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.

O estudo original

Prediction of non-responders to oral appliance treatment of obstructive sleep apnea: a pilot study

Ulrik Leidland Opsahl, Morten Berge, Sverre Lehmann, Bjørn Bjorvatn, Anders Johansson

Descritores MeSH

  • Patient Compliance
  • Occlusal Splints
  • Sleep Apnea, Obstructive
  • Continuous Positive Airway Pressure
  • Middle Aged
  • Adult
  • Treatment Outcome
  • Polysomnography
  • Cross-Over Studies
  • Pilot Projects

Veja também

Estudos relacionados