Prediction of non-responders to oral appliance treatment of obstructive sleep apnea: a pilot study
NeurologiaPor ScienceMed · · a partir do resumo dos autores
Resumo original em inglês
O que aconteceu
Several clinically available variables have been identified as predictors of non-response to oral appliance (OA) treatment, including endotypical traits such as severe upper airway collapsibility, unstable ventilatory control, and low arousal threshold. This study aimed to identify potential predictors of non-response to OA treatment in patients with OSA non-adherent to treatment with positive airway pressure.
Patients in this study were initially treated with OAs with and without elastic bands in a crossover design. Subsequently, each patient selected their preferred treatment modality for continued therapy based on subjective preferences. The chosen OA treatment. The chosen OA treatment modality was titrated optimally based on reduction of REI. Patients not reaching > 50% reduction of REI from baseline were classified as non-responders. Statistical analyses were conducted using Student's t-test and Pearson's chi-squared test to assess differences in baseline variables between responders and non-responders, and logistic regression analyses were performed to investigate variables associated with not responding to OA treatment.
NCT05987618 (clinicaltrials.gov).
O que encontraram
Overall, 63.2% (n = 36) of the patients were responders to OA treatment following titration. Smaller distance from habitual bite position to maximal retruded position (Odds ratio: 0.28, p = 0.016), positional OSA (Odds ratio: 0.94, p = 0.024) and a higher number of the endotypical OSA traits severe collapsibility, high loop gain and low arousal threshold (Odds ratio: 7.41, p = 0.038), were found to predict non-response to OA treatment.
Por que isso importa
These novel findings suggest that severe upper airway collapsibility, high loop gain and low arousal threshold, identified through clinically available variables, appear to be important predictors of non-response to OA treatment, along with short distance from habitual bite position to maximal retruded position and positional OSA.
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
Prediction of non-responders to oral appliance treatment of obstructive sleep apnea: a pilot study
Ulrik Leidland Opsahl, Morten Berge, Sverre Lehmann, Bjørn Bjorvatn, Anders Johansson
Descritores MeSH
- Patient Compliance
- Occlusal Splints
- Sleep Apnea, Obstructive
- Continuous Positive Airway Pressure
- Middle Aged
- Adult
- Treatment Outcome
- Polysomnography
- Cross-Over Studies
- Pilot Projects
Veja também
Estudos relacionados
- To compare different non-surgical treatment modalities on treatment of obstructive sleep apnea: A systematic review and meta-analysis
- Efeito da terapia miofuncional orofacial com automonitoramento no índice de apneia-hipopneia em pacientes com apneia obstrutiva leve a moderada do sono: estudo multicêntrico randomizado controlado
- What's leak got to do with it? Association of mask leak and positive airway pressure adherence from the homepap study
- Effects of simulated arch constriction on upper airway function during sleep