Precisão das estratégias diagnósticas para detecção da infecção por Schistosoma mansoni no Brasil: Revisão sistemática e meta-análise
InfectologiaPor ScienceMed · · · a partir do resumo dos autores
Resumo original em inglês
O que aconteceu
Schistosoma mansoni infection remains a major public health concern in Brazil. Accurate diagnostic methods are essential for monitoring transmission and guiding control and elimination strategies. This systematic review and meta-analysis aimed to assess the performance of diagnostic tests used for S. mansoni infection in Brazil.
Studies conducted in endemic areas of Brazil that used parasitological methods as the reference standard, reported sensitivity and specificity, and were published through October 2024, were included in the analysis. Diagnostic performance was synthesized using univariate and multivariate meta-analyses, and risk of bias was assessed with QUADAS-2.
O que encontraram
Thirty-three studies were included; most were conducted in Minas Gerais (63%). The main reference standard was Kato-Katz alone (48%) or combined with other parasitological methods (42.4%). Enzyme-linked immunosorbent (ELISA)-SEA results showed higher accuracy than ELISA-SWAP (81% vs 68%), although both exhibited heterogeneity above 80%. Point-of-care circulating cathodic antigen with trace results interpreted as positive (POC-CCA+) or negative (POC-CCA-) showed similar accuracy (70% vs 73%, respectively), with heterogeneity exceeding 80%. For conventional PCR, PCR-ELISA, real-time PCR, and loop-mediated isothermal amplification (LAMP), accuracy ranged from 67% to 82% (heterogeneity: > 90%. In multivariate analysis, conventional PCR had the highest diagnostic odds ratio (DOR: 99.4), followed by PCR-ELISA (DOR: 12.4), whereas the two POC-CCA reading criteria resulted in lower values (trace-positive: 8.5, trace-negative: 6.1).
Por que isso importa
Overall, these observations support the use of combined diagnostic strategies and underscore the need for multicenter, methodologically rigorous studies to strengthen surveillance, control, and elimination efforts for Schistosoma mansoni infection in Brazil.
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
Accuracy of diagnostic strategies for detecting Schistosoma mansoni infection in Brazil: A systematic review and meta-analysis
Tália Santana Machado de Assis, Mariana Lourenço Freire, Sarah Nascimento Silva, Daniel Moreira de Avelar, Gláucia Cota, Ana Rabello
Descritores MeSH
- Schistosomiasis mansoni
- Schistosoma mansoni
- Brazil
- Enzyme-Linked Immunosorbent Assay
- Humans
- Animals
- Sensitivity and Specificity
- Antigens, Helminth
Veja também
Estudos relacionados
- Evaluating the efficacy of different praziquantel treatment regimens using egg and circulating anodic antigen (CAA) detection methods in a Schistosoma mansoni endemic area in northeastern Brazil
- Limited efficacy of repeated praziquantel treatment in Schistosoma mansoni infections as revealed by highly accurate diagnostics, PCR and UCP-LF CAA (RePST trial)
- Diagnostic tests for human Schistosoma mansoni and Schistosoma haematobium infection: a systematic review and meta-analysis
- A Mini-Review on Elisa-Based Diagnosis of Schistosomiasis