
Outcomes of conduction system pacing compared to right ventricular pacing as a primary strategy for treating bradyarrhythmia: systematic review and meta-analysis
CardiologiaPor ScienceMed · · a partir do resumo dos autores
Resumo original em inglês
O que aconteceu
Right ventricular pacing (RVP) may cause electrical and mechanical desynchrony leading to impaired left ventricular ejection fraction (LVEF). We investigated the outcomes of RVP with His bundle pacing (HBP) and left bundle branch pacing (LBBP) for patients requiring a de novo permanent pacemaker (PPM) for bradyarrhythmia.
O que encontraram
Systematic review of randomized clinical trials and observational studies comparing HBP or LBP with RVP for de novo PPM implantation between 01 January 2013 and 17 November 2020 was performed. Random and fixed effects meta-analyses of the effect of pacing technology on outcomes were performed. Study outcomes included all-cause mortality, heart failure hospitalization (HFH), LVEF, QRS duration, lead revision, atrial fibrillation, procedure parameters, and pacing metrics. Overall, 9 studies were included (6 observational, 3 randomised). HBP compared with RVP was associated with decreased HFH (risk ratio [RR] 0.68, 95% confidence interval [CI] 0.49-0.94), preservation of LVEF (mean difference [MD] 0.81, 95% CI - 1.23 to 2.85 vs. - 5.72, 95% CI - 7.64 to -3.79), increased procedure duration (MD 15.17 min, 95% CI 11.30-19.04), and increased lead revisions (RR 5.83, 95% CI 2.17-15.70, p = 0.0005). LBBP compared with RVP was associated with shorter paced QRS durations (MD 5.6 ms, 95% CI - 6.4 to 17.6) vs. (51.0 ms, 95% CI 39.2-62.9) and increased procedure duration (MD 37.78 min, 95% CI 20.04-55.51).
Por que isso importa
Of the limited studies published, this meta-analysis found that HBP and LBBP were superior to RVP in maintaining physiological ventricular activation as an initial pacing strategy.
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
Outcomes of conduction system pacing compared to right ventricular pacing as a primary strategy for treating bradyarrhythmia: systematic review and meta-analysis
Amr Abdin, Suleman Aktaa, Davor Vukadinović, Elena Arbelo, Harran Burri, Michael Glikson, Christian Meyer, Theresa Munyombwe, Jens Cosedis Nielsen, Christian Ukena et al.
Descritores MeSH
- Bradycardia
- Atrial Fibrillation
- Cardiac Pacing, Artificial
- Electrocardiography
- Humans
- Stroke Volume
- Ventricular Function, Left
- Cardiac Conduction System Disease
- Treatment Outcome
- Bundle of His
Veja também
Estudos relacionados
- Left bundle branch area pacing for heart failure patients requiring cardiac resynchronization therapy: A meta-analysis
- Safety and efficacy of left bundle branch area pacing compared with right ventricular pacing in patients with bradyarrhythmia and conduction system disorders: Systematic review and meta-analysis
- His-Purkinje conduction system pacing: A systematic review and network meta-analysis in bradycardia and conduction disorders
- Updated Meta-Analysis of Left Bundle Branch Area Pacing Versus Right Ventricular Pacing in Conduction System Disorders: Insights From New Evidence
- Resultados do sistema de condução e estimulação ventricular direita nas indicações de bradiarritmia: Revisão sistemática e metanálise dos estudos prospectivos pareados e randomizados