Oscillometry for the diagnosis of asthma in children: a systematic review

Imunologia e Alergia
Imagem de arquivo, ilustrativa — não é do estudo. Radiografia de tórax de pulmões saudáveis. N.a. Radiology by Dr. Johan Verbeken. Scan and image editing by Vincent Mia Edie Verheyen · domínio público · Wikimedia Commons

Revisão sistemáticaNível 1 · Evidência consolidadaEuropean respiratory review : an official journal of the European Respiratory Society29 abr 20261 citações

Por ScienceMed · · a partir do resumo dos autores

Salvar

Resumo original em inglês

O que aconteceu

Diagnosing asthma in children and young people (CYP) remains challenging. Oscillometry is a promising tool and is feasible from 2 years of age. European Respiratory Society (ERS) technical standards and bronchodilator response (BDR) oscillometry thresholds have been published, but diagnostic accuracy is not established.

We systematically reviewed studies comparing oscillometry and spirometry in CYP under investigation for asthma. Reference standards were positive BDR or positive methacholine challenge test (MCT). Primary aims were to investigate the sensitivity and specificity of current ERS oscillometry thresholds (>40% decrease in resistance at 5 Hz (R 5), >50% increase in reactance at 5 Hz (X 5) or >80% decrease in the area under the reactance curve); secondary aims were to identify oscillometry threshold values optimising both sensitivity and specificity.

O que encontraram

11 studies were included; six (n=992 CYP) utilised BDR and five (n=531 CYP) MCT as reference standard. Meta-analysis was not possible due to heterogeneity of results reported. In two studies using current ERS BDR thresholds, zero sensitivity and high specificity (>85%) were observed. In weighted regression analyses of BDR studies, a 17.0% decrease in resistance at 5-6 Hz had sensitivity and specificity of 71.6% (95% CI 69.7-73.7%); a 20.2% increase in X 5 had sensitivity and specificity of 68.6% (95% CI 66.6-70.8%). Similarly, 27.7% increase in R 5 had sensitivity and specificity of 73.6% (95% CI 71.9-75.3%) for MCT.

Por que isso importa

Currently recommended ERS thresholds for oscillometry BDR have low sensitivity. Proposed thresholds for defining positive BDR and MCT by oscillometry require prospective validation and adoption of standards for measuring and reporting oscillometry parameters in future diagnostic comparative studies.

Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.

O estudo original

Oscillometry for the diagnosis of asthma in children: a systematic review

Senali Y Seneviratne, Saxon Law-Gleen, Jonathan Broomfield, Pip Divall, Pooja Devani, Francine M Ducharme, Erol A Gaillard