Optimizing tourniquet pressures in knee arthroscopy: an international survey on current practice and a double-blind randomized trial
CirurgiaPor ScienceMed · · a partir do resumo dos autores
Resumo original em inglês
O que aconteceu
Pneumatic tourniquets improve surgical visualization during knee arthroscopy, but fixed high pressures may increase postoperative pain. This study investigated whether a minimal effective individualized occlusion pressure (MEIOP), calculated as limb occlusion pressure plus a safety margin, maintains surgical field quality while reducing pain compared to a standardized occlusion pressure (SOP).
A preliminary survey of 79 orthopaedic surgeons identified 350 mmHg as the routine SOP. In a subsequent double-blind randomized clinical trial, patients undergoing elective knee arthroscopy were assigned to SOP (350 mmHg) or MEIOP, defined as Doppler-derived limb occlusion pressure plus a safety margin (mean ≈ 230 mmHg). Outcomes included surgical field quality, postoperative using a visual analog scale (VAS) up to 15 days, overall 15-day pain perception, and analgesic consumption.
O que encontraram
Both groups achieved 100% excellent surgical field ratings. Pain trajectories differed significantly between groups over time (group × time interaction, p = 0.022). The MEIOP group experienced significantly lower pain at discharge (~ 6 h; p = 0.013, d = 1.14) and lower overall 15-day pain perception (p = 0.043, d = 0.89). Analgesic consumption showed a consistent descriptive trend favoring MEIOP throughout follow-up.
Por que isso importa
This proof-of-concept study suggests that individualizing tourniquet pressure using predefined MEIOP protocol preserves satisfactory surgical visualization and is associate with lower postoperative pain compared with a standard high-pressure protocol. This trial was prospectively registered at the Brazilian Clinical Trials Registry (ReBEC; RBR-4xd6cxm).
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
Optimizing tourniquet pressures in knee arthroscopy: an international survey on current practice and a double-blind randomized trial
Heber Oliveira Cardoso Filho, Bruno Fajardo do Nascimento, Rodrigo Hohl, Vinicius Novais Rocha, Manoel Carlos Couto de Araujo, Rhai A Arriel, Gabriel Dias Mendes Andrade, Moacir Marocolo
Descritores MeSH
- Postoperative Pain
- Knee Joint
- Arthroscopy
- Tourniquets
- Adult
- Middle Aged
- Pain Measurement
- Pressure
- Surveys and Questionnaires
- Male
Veja também
Estudos relacionados
- Effects of special waterproof layer under tourniquet cuff on the incidence of burns and pain intensity and satisfaction of operating room staff in knee arthroscopic surgeries: a randomized clinical trial
- Efficacy and systemic safety of adding intra-articular dexmedetomidine as adjuvant therapy to bupivacaine for post-operative analgesia in knee arthroscopic procedures: a systematic review and meta-analysis
- Liposomal bupivacaine in peri-articular injection reduces opioid consumption and improves early prognosis of total knee arthroplasty: a randomized controlled trial
- Efeito de diferentes concentrações de bupivacaína lipossômica no bloqueio superior do tronco guiado por ultrassom na analgesia e mobilidade pós-operatórias: a protocolo de ensaio controlado randomizado duplo-cego para artroscopia do ombro