ScienceMed®
Imagem de arquivo, ilustrativa: Radiografia histórica do joelho de um menino (1896)

Optimizing tourniquet pressures in knee arthroscopy: an international survey on current practice and a double-blind randomized trial

Cirurgia
Imagem de arquivo, ilustrativa — não é do estudo. Radiografia histórica do joelho de um menino (1896). Wellcome Collection · CC BY 4.0 · Wikimedia Commons

Ensaio clínico randomizadoNível 2 · Nova evidênciaInternational orthopaedics27 jun 20260 citações

Por ScienceMed · · a partir do resumo dos autores

Salvar

Resumo original em inglês

O que aconteceu

Pneumatic tourniquets improve surgical visualization during knee arthroscopy, but fixed high pressures may increase postoperative pain. This study investigated whether a minimal effective individualized occlusion pressure (MEIOP), calculated as limb occlusion pressure plus a safety margin, maintains surgical field quality while reducing pain compared to a standardized occlusion pressure (SOP).

A preliminary survey of 79 orthopaedic surgeons identified 350 mmHg as the routine SOP. In a subsequent double-blind randomized clinical trial, patients undergoing elective knee arthroscopy were assigned to SOP (350 mmHg) or MEIOP, defined as Doppler-derived limb occlusion pressure plus a safety margin (mean ≈ 230 mmHg). Outcomes included surgical field quality, postoperative using a visual analog scale (VAS) up to 15 days, overall 15-day pain perception, and analgesic consumption.

O que encontraram

Both groups achieved 100% excellent surgical field ratings. Pain trajectories differed significantly between groups over time (group × time interaction, p = 0.022). The MEIOP group experienced significantly lower pain at discharge (~ 6 h; p = 0.013, d = 1.14) and lower overall 15-day pain perception (p = 0.043, d = 0.89). Analgesic consumption showed a consistent descriptive trend favoring MEIOP throughout follow-up.

Por que isso importa

This proof-of-concept study suggests that individualizing tourniquet pressure using predefined MEIOP protocol preserves satisfactory surgical visualization and is associate with lower postoperative pain compared with a standard high-pressure protocol. This trial was prospectively registered at the Brazilian Clinical Trials Registry (ReBEC; RBR-4xd6cxm).

Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.

O estudo original

Optimizing tourniquet pressures in knee arthroscopy: an international survey on current practice and a double-blind randomized trial

Heber Oliveira Cardoso Filho, Bruno Fajardo do Nascimento, Rodrigo Hohl, Vinicius Novais Rocha, Manoel Carlos Couto de Araujo, Rhai A Arriel, Gabriel Dias Mendes Andrade, Moacir Marocolo

Descritores MeSH

  • Postoperative Pain
  • Knee Joint
  • Arthroscopy
  • Tourniquets
  • Adult
  • Middle Aged
  • Pain Measurement
  • Pressure
  • Surveys and Questionnaires
  • Male

Veja também

Estudos relacionados