Occlusal outcome of orthodontic treatment: a systematic review with meta-analyses of randomized trials
MedicinaPor ScienceMed · · a partir do resumo dos autores
Resumo original em inglês
O que aconteceu
Several appliances or treatment protocols are marketed to either patients or orthodontists as being associated with improved orthodontic outcomes. However, clinical decision-making should be based on robust scientific evidence and not marketing claims or anecdotal evidence.
To identify appliances/protocols being associated with improved outcomes of fixed appliance treatment.
Unrestricted literature searches in seven databases/registers for human studies until March 2024.
Randomized or quasi-randomized clinical trials on human patients of any age, sex, or ethnicity receiving comprehensive orthodontic treatment with fixed appliances and assessing occlusal outcome with either the Peer Assessment Rating (PAR) or the American Board of Orthodontics-Objective Grading System (ABO-OGS) index.
Duplicate/independent study selection, data extraction, and risk of bias assessment with the Cochrane RoB 2 tool. Random-effects meta-analyses of averages or mean differences with their 95% Confidence Intervals (CI), followed by meta-regression/subgroup/sensitivity analyses and assessment of the quality of clinical recommendations with the Grades of Recommendations, Assessment, Development, and Evaluation (GRADE) approach.
PROSPERO (CRD42024525088).
O que encontraram
Data from 20 small- to moderately-sized trials covering 1470 patients indicated that orthodontic treatment with fixed appliances is effective and results on average in a final PAR score of 6.0 points (95% CI 3.9-8.2 points), an absolute PAR reduction of 23.0 points (95% CI 15.6-30.4 points), a % PAR reduction of 82.6% (95% CI 70.8%-94.4%), and an absolute ABO-OGS score of 18.9 points (95% CI 11.7-26.2 points). However, very high between-study heterogeneity (I2 > 75%) was seen for both PAR and ABO-OGS. Extraction treatment was associated with significantly better occlusal outcome than non-extraction treatment with ABO-OGS (12.9 versus 16.6 points; P = .02). There was no statistically significant difference in occlusal outcome with (i) 0.018″-slot or 0.022″-slot brackets; (ii) customized or prefabricated brackets; (iii) anchorage reinforcement with temporary anchorage devices; (iv) use of vibrational adjuncts; and (v) aligners or fixed appliances (P > .05 in all instances), while small benefits were seen with indirectly bonded brackets.
Por que isso importa
Considerable between-study heterogeneity exists in the reported occlusal outcome of fixed appliance treatment, and different appliances or adjuncts have little effect on this. Standardization and/or automatization of the scoring procedures for PAR and ABO-OGS might help to improve consistency and reliability of outcome measurement in orthodontic trials.
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
Occlusal outcome of orthodontic treatment: a systematic review with meta-analyses of randomized trials
S N Papageorgiou, Theodora Giannakopoulou, Theodore Eliades, Vaska Vandevska-Radunovic
Descritores MeSH
- Malocclusion
- Orthodontics, Corrective
- Humans
- Orthodontic Appliances
- Randomized Controlled Trials as Topic
- Orthodontic Appliances, Fixed
- Treatment Outcome
- Dental Occlusion