ScienceMed®
Imagem de arquivo, ilustrativa: Ilha de Java à noite, vista da Estação Espacial Internacional

Níveis de ruído da sala de operação em anestesia: revisão sistemática e metanálise

Medicina
Imagem de arquivo, ilustrativa — não é do estudo. Ilha de Java à noite, vista da Estação Espacial Internacional. NASA · domínio público · Wikimedia Commons

MetanáliseNível 1 · Evidência consolidadaBritish journal of anaesthesia22 set 20260 citações

Por ScienceMed · · a partir do resumo dos autores

Salvar

Resumo original em inglês

O que aconteceu

Intraoperative noise is an occupational hazard with the potential to compromise anaesthetist performance and patient safety. The WHO recommends hospital sound exposure ≤ 35 dB LAeq (A-weighted equivalent continuous sound level), yet noise levels routinely exceed this level. This systematic review and meta-analysis aimed to determine intraoperative noise levels worldwide.

Five databases were searched from inception to May 2026, in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Studies were eligible for inclusion if they included surgical specialty and a measure of noise sampled recorded with validated sound metres. Studies were eligible for meta-analysis if they included a mean time-weighted average. Two authors undertook searches and risk-of-bias assessment. Meta-regression estimated pooled means, heterogeneity, and variance.

O que encontraram

Fifty studies met the inclusion criteria in the systematic review, with 28 studies providing 43 unique datasets subclassified by type of surgical procedure for analysis. The pooled random-effects mean intraoperative noise level was 70.7 A-weighted dB [dB(A)] (95% CI 69.0-72.3). Subgroup analysis demonstrated the highest exposures in otolaryngology at 78.8 dB(A) (95% CI 72.8-84.7) and orthopaedics at 73.3 dB(A) (95% CI 68.9-77.8). Meta-regression confirmed surgical specialty as a significant predictor of mean exposure (Q=25.8, degrees of freedom=6, P=0.0002).

Por que isso importa

Anaesthetists are consistently exposed to intraoperative sound levels exceeding WHO guidelines, particularly in high-intensity specialties such as orthopaedics and otolaryngology. These findings provide a specialty-specific synthesis of noise exposure and highlight the need for targeted interventions, standardised measurement, and research linking exposure to clinical outcomes.

Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.

O estudo original

Operating room noise levels in anaesthesia: a systematic review and meta-analysis

Asher Dixon, Nicolas A Sieben, Samuel Smith, Jing Sun

Descritores MeSH

  • Anesthesia
  • Noise, Occupational
  • Operating Rooms
  • Occupational Exposure
  • Humans

Estudos relacionados