Moisture mitigation using a vented liner and a vented socket system for individuals with transfemoral amputation

Medicina

Ensaio clínico randomizadoNível 2 · Nova evidênciaScientific reports2 out 202312 citações

Por ScienceMed · · a partir do resumo dos autores

Salvar

Resumo original em inglês

O que aconteceu

Sweating and heat buildup at the skin-liner interface is a major challenge for persons with limb loss. Liners made of heat-non-conducting materials may cause sweating of the residual limb and may result in liners slipping off the skin surface especially on a warm day or during high activity, causing skin breakdown and affecting limb health. To address this, we evaluated the efficacy of the vented liner-socket system (VS, Össur) compared to Seal-In silicone liner and non-vented socket (nVS, Össur) in reducing relative humidity (RH) during increased sweat. Nine individuals with limb loss using nVS were randomized to VS or nVS and asked for activity in a 20-min treadmill walk. RH was significantly attenuated (p = 0.0002) and perceived sweating, as reported by prosthesis users, improved (p = 0.028) with VS, patient-reported comprehensive lower limb amputee socket survey (CLASS) outcomes to determine the suspension, stability, and comfort were not significantly different between VS and nVS. There are limited rigorous scientific studies that clearly provide evidence-based guidelines to the prosthetist in the selection of liners from numerous available options. The present study is innovative in clearly establishing objective measures for assessing humidity and temperatures at the skin-liner interface while performing activity. As shown by the measured data and perceived sweat scores provided by the subjects based on their daily experience, this study provided clear evidence establishing relative humidity at the skin-liner interface is reduced with the use of a vented liner-socket system when compared to a similar non-vented system.

Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.

O estudo original

Moisture mitigation using a vented liner and a vented socket system for individuals with transfemoral amputation

Surya C Gnyawali, Jeffrey A Denune, Bryce Hockman, Jóna Valgerður Kristjánsdóttir, Margrét Sól Ragnarsdóttir, Lava R Timsina, Subhadip Ghatak, Knut Lechler, Chandan K Sen, Sashwati Roy

Descritores MeSH

  • Amputees
  • Artificial Limbs
  • Humans
  • Prosthesis Design
  • Tibia
  • Amputation, Surgical
  • Lower Extremity
  • Amputation Stumps