ScienceMed®
Imagem de arquivo, ilustrativa: Interneurônios inibitórios do hipocampo de camundongo, em microscopia de fluorescência

Longitudinal Phospho-tau217 Predicts Amyloid Positron Emission Tomography in Asymptomatic Alzheimer's Disease

Neurologia
Imagem de arquivo, ilustrativa — não é do estudo. Interneurônios inibitórios do hipocampo de camundongo, em microscopia de fluorescência. NIH · domínio público · Wikimedia Commons

Estudo observacionalNível 2 · Nova evidênciaThe journal of prevention of Alzheimer's disease1 jan 202443 citações

Por ScienceMed · · a partir do resumo dos autores

Salvar

Resumo original em inglês

O que aconteceu

Blood-based AD biomarkers such as plasma P-tau217 are increasingly used in clinical trials as a screening tool.

To assess the utility of an electrochemiluminescence (ECL) immunoassay in predicting brain amyloid PET status in cognitively unimpaired individuals.

Plasma samples collected at baseline, week 12, and week 240 or endpoint originated from the Anti-Amyloid Treatment in Asymptomatic Alzheimer's Disease (A4) trial and the companion Longitudinal Evaluation of Amyloid Risk and Neurodegeneration (LEARN) study.

Both A4 and LEARN enrolled eligible cognitively unimpaired persons 65 to 85 years. Individuals with elevated brain amyloid PET levels were eligible for the A4 Study, while those without elevated brain amyloid PET levels were eligible for the LEARN Study.

Participants in the A4 Study received intravenous solanezumab (up to 1600 mg) or placebo every 4 weeks. The LEARN Study is an observational study without intervention.

Plasma P-tau217 concentration levels from A4 Study participants were measured using an ECL immunoassay. Receiver Operating Characteristic (ROC) curve analysis was performed for each biomarker against amyloid positivity, defined by ≥22 CL and ≥ 33 CL.

O que encontraram

Receiver operating characteristic curve (ROC) analysis indicates high diagnostic value of P-tau217 in individuals with amyloid PET ≥ 20 (Area under the ROC (AUROC): 0.87) and ≥ 33 CL (AUROC: 0.89). Repeated testing with the placebo group taken 12 weeks apart (range: 68 to 143 days) and the LEARN participants taken between 1.4 and 1.75 years resulted in a strong positive correlation (Corr. 0.91 (0.90 to 0.92)).

Por que isso importa

An ECL immunoassay testing plasma P-tau217 accurately predicts amyloid PET positivity in cognitively unimpaired individuals. Our future analyses aim to determine if use of this assay may reduce the screening burden of preclinical individuals into anti-amyloid clinical trials.

Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.

O estudo original

Longitudinal Phospho-tau217 Predicts Amyloid Positron Emission Tomography in Asymptomatic Alzheimer's Disease

R A Rissman, M C Donohue, O Langford, R Raman, S Abdel-Latif, R Yaari, K C Holdridge, J R Sims, D Molina-Henry, G Jimenez-Maggiora et al.

Descritores MeSH

  • Alzheimer Disease
  • tau Proteins
  • Positron-Emission Tomography
  • Biomarkers
  • Humans
  • Longitudinal Studies
  • Male
  • Amyloid beta-Peptides
  • Aged
  • Antibodies, Monoclonal, Humanized

Veja também