O que aconteceu

Left bundle-branch pacing (LBBP) has been proposed as an alternative to biventricular pacing (BiVP) for patients with heart failure with left bundle-branch block (LBBB). However, robust clinical evidence from randomized clinical trials is lacking.

To evaluate the long-term clinical outcomes of LBBP and BiVP.

This multicenter, prospective, randomized clinical trial enrolled 200 patients at 6 centers in China with a left ventricular ejection fraction (LVEF) of 35% or less and LBBB from October 2020 to March 2022. This study was took place from October 2020 to September 2024. These data were analyzed September 2024 to December 2024.

Patients were randomly assigned in a 1:1 ratio to receive either LBBP or BiVP.

Chinese Clinical Trial Registry identifier: ChiCTR2000036554.

O que encontraram

The primary end point was the time to death from any cause or heart failure hospitalization (HFH). The secondary end points included all-cause death, HFH, echocardiographic response (absolute increase in LVEF ≥5%), and super response (absolute increase in LVEF ≥15% or improvement of LVEF to ≥50%) rates.

Of the 200 included patients, 136 were male and 64 were female. The success rate was 98% in the LBBP group and 94% in the BiVP group (P = .28). The median follow-up duration was 36 (range, 33-39) months. The primary end point of time to death or HFH was significantly lower in the LBBP group compared with BiVP (8% vs 28%; hazard ratio [HR], 0.26; 95% CI, 0.12-0.57; P < .001). There was no significant difference in all-cause mortality between the groups (2.0% vs 5.0%; HR, 0.40; 95% CI, 0.08-2.04; P = .25). However, LBBP significantly reduced the risk of HFH (7.0% vs 28.0%; HR, 0.23; 95% CI, 0.10-0.52; P < .001). The echocardiographic response rates were similar in both groups (86.0% vs 81.0%; P = .34) but the super-response rate was higher in the LBBP group (55.0% vs 36.0%; P < .007).

Por que isso importa

In this study, LBBP was superior to BiVP in reducing the risk of death or HFH in patients with LBBB and severely reduced LVEF. Further trials are warranted in this patient population.

Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.

O estudo original

Long-Term Outcomes of Left Bundle-Branch Pacing vs Biventricular Pacing in Heart Failure: The HeartSync-LBBP Randomized Clinical Trial

Xueying Chen, Xi Liu, Ruogu Li, Zhongkai Wang, Yixiu Liang, Lei Zhang, Wei Wang, Jin Bai, Jingfeng Wang, Shengmei Qin et al.

Descritores MeSH

  • Bundle-Branch Block
  • Heart Failure
  • Cardiac Pacing, Artificial
  • Cardiac Resynchronization Therapy
  • Aged
  • Male
  • Middle Aged
  • Prospective Studies
  • Stroke Volume
  • Ventricular Function, Left

Veja também

Estudos relacionados