ScienceMed®
Imagem de arquivo, ilustrativa: Radiografia de um quadril normal: a cabeça do fêmur encaixada no acetábulo

Long-term follow-up of bone density changes in total hip arthroplasty: comparative analysis from a randomized controlled trial of a porous titanium construct shell vs. a porous coated shell

Cirurgia
Imagem de arquivo, ilustrativa — não é do estudo. Radiografia de um quadril normal: a cabeça do fêmur encaixada no acetábulo. Mikael Häggström · CC0 · Wikimedia Commons

Ensaio clínico randomizadoNível 2 · Nova evidênciaInternational orthopaedics7 set 20244 citações

Por ScienceMed · · a partir do resumo dos autores

Salvar

Resumo original em inglês

O que aconteceu

Periacetabular bone loss poses a considerable challenge in the longevity and stability of acetabular implants used in total hip arthroplasty (THA). Innovations in implant design, specifically the introduction of three-dimensional (3D) porous titanium constructs, might reduce bone resorption. The purpose of this study was to build upon our previous randomized controlled trial, which found no change in periacetabular bone loss between a 3D porous none-hydroxyapatite coated titanium cup and a standard porous hydroxyapatite coated cup over a two year follow-up period by extending the follow-up duration to ten years post-surgery.

This was a single-centre, long-term follow-up study conducted over a ten year period in patients who had previously participated in a randomized controlled trial comparing a 3D porous titanium construct shell (PTC group) with a standard porous hydroxyapatite coated titanium shell (PC-group). The primary outcome measured was the change in bone mineral density (BMD) within four specific periacetabular zones, alongside overall bone loss, which was assessed through BMD in the lumbar spine at two, six and ten years postoperatively. Secondary outcomes included clinical outcome measures.

O que encontraram

In total, 18 in the PTC and 20 in the PC group were analysed for the primary endpoint up to ten years. The mean bone mineral density in zones 1-4 was 3.7% higher in the PTC group than in the PC group at six years postoperatively and 12.0% higher at ten years. Clinical outcomes, and the frequency of adverse events did not differ between the groups.

Por que isso importa

The PTC group displayed superior long-term bone preservation compared to the PC group while maintaining similar clinical outcomes up to ten years postoperatively. Although with a small sample size, our findings suggest that porous titanium cups have the potential to minimize BMD loss around the cup which could contribute to improving THA outcomes and implant durability.

Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.

O estudo original

Long-term follow-up of bone density changes in total hip arthroplasty: comparative analysis from a randomized controlled trial of a porous titanium construct shell vs. a porous coated shell

Michael Axenhus, Mats Salemyr, Sebastian Mukka, Martin Magnéli, Olof Sköldenberg

Descritores MeSH

  • Hip Prosthesis
  • Prosthesis Design
  • Titanium
  • Arthroplasty, Replacement, Hip
  • Bone Density
  • Humans
  • Male
  • Middle Aged
  • Porosity
  • Treatment Outcome

Veja também

Estudos relacionados