Left bundle branch area pacing using a lumenless lead: A systematic literature review and meta-analysis
CardiologiaPor ScienceMed · · a partir do resumo dos autores
Resumo original em inglês
O que aconteceu
Although left bundle branch area pacing (LBBAP) has been shown to be a feasible option for delivering physiological pacing, data are largely limited to single-center reports. The aim of this analysis was to systematically assess the safety and efficacy of LBBAP with the Model 3830 lead among primarily bradycardia patients.
O que encontraram
PubMed, Embase, Cochrane Library, and Google Scholar were searched for full-text articles on LBBAP using the SelectSecure Model 3830 lumenless lead. Rates and means were estimated using random- and mixed-effects models. Of 3395 articles, 53 met inclusion criteria, representing 6061 patients undergoing an implant attempt. Average patient age was 68.1 years (95% CI: 66.6, 69.6) and 53.1% were male (95% CI: 50.5%, 55.7%). The average implant success rate among bradycardia-indicated patients was 92.7% (95% CI: 89.5%, 94.9%). The overall estimated procedural adverse event rate was 2.5% (95% CI: 1.1%, 5.4%). The estimated septal perforation rate at implant was 1.6% (95% CI: 1.0%, 2.6%) with no adverse clinical sequelae reported. Pacing thresholds were low at implant (0.67 V [95% CI: 0.64, 0.70]) and remained stable through 12 months (0.76 V [95% CI: 0.72, 0.80]). Among bradycardia-indicated patients, LVEF remained stable from baseline to post-implant (59.5% [95% CI: 57.9%, 61.1%] vs. 60.1% [95% CI: 58.5%, 61.7%]).
Por que isso importa
This meta-analysis including 6061 patients implanted with a Model 3830 lead for LBBAP found an average implant success rate of 92.7% and a procedural adverse event rate of 2.5% with stable electrical parameters and LVEF post-implant.
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
Left bundle branch area pacing using a lumenless lead: A systematic literature review and meta-analysis
Kenneth A Ellenbogen, Dedra H Fagan, Patrick Zimmerman, Pugazhendhi Vijayaraman
Descritores MeSH
- Heart Rate
- Bradycardia
- Cardiac Pacing, Artificial
- Action Potentials
- Female
- Humans
- Male
- Middle Aged
- Pacemaker, Artificial
- Risk Factors
Veja também
Estudos relacionados
- Stylet-driven leads compared with lumenless leads for left bundle branch area pacing: a systematic review and meta-analysis
- Atualizando a estimulação ventricular direita para área do ramo esquerdo em cardiomiopatia induzida por marcapasso: revisão sistemática e meta-análise
- Left Bundle Branch Area Pacing Versus Right Ventricular Pacing in Patients With Atrioventricular Block: A Systematic Review and Meta-Analysis
- Clinical and electrical outcomes of conduction system pacing versus right ventricular pacing in atrioventricular block: a systematic review and meta-analysis