Despite surgically successful total knee arthroplasties, up to 20% of patients are dissatisfied postoperatively. A factor thought to influence dissatisfaction is the alignment strategy utilized. Inconsistencies in safe zone definitions between neutral and kinematic alignment strategies have limited previous systematic reviews. The systematic review aimed to identify whether different intraoperative coronal alignment safe zones influence patient-reported and functional outcomes.
A literature search in Medline, Scopus, PubMed, Web of Science, CINAHL, and Cochrane databases was conducted in November 2024. Articles reporting patient outcomes at a minimum 12-month postoperatively, and coronal alignment safe zones were included. The Methodological Index for Non-Randomized Studies was used to conduct a quality assessment for each article. The Forgotten Joint Score pain measures, the Oxford Knee Score, and knee flexion were compared between safe zones. Random-effects network meta-analyses were conducted with treatment rankings, and a back-calculation method determined consistency between direct and indirect measures. A publication bias analysis was conducted for each outcome measure. Of the 26 studies eligible, 13 (knees n = 1,653, approximately 57% women) were included in the network meta-analysis.
O que encontraram
There were four coronal safe zones identified: 0° (neutral), ± 3°, 6° varus to 3° valgus (6VR-3VL), and unrestricted. The 6VR-3VL was superior for the Forgotten Joint Score (standardized mean difference [SMD] = 1.59, 95% confidence interval [95% CI] = 0.25 to 2.92), pain measures (SMD = -0.85, 95% CI = -1.64 to -0.05), and knee flexion (SMD = -1.04, 95% CI = 0.08 to 1.99). There was significant publication bias in studies reporting pain. Unrestricted alignment was associated with greater knee flexion (SMD = 0.28, 95% CI = 0.02 to 0.53).
Por que isso importa
The outcomes suggest 6VR-3VL had consistently better patient outcomes, and unrestricted alignment had better functional outcomes, than neutral alignment. This was potentially due to better restoration of the patient's prearthritic alignment.
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
Intraoperative Coronal Alignment Safe Zones Influence Patient Outcomes Following Total Knee Arthroplasty: A Systematic Review and Network Meta-Analysis
Isobel H Oon, Joseph T Lynch, Cody Lindsay, Wayne Spratford, Celeste E Coltman, Jennie M Scarvell
Descritores MeSH
- Knee Joint
- Arthroplasty, Replacement, Knee
- Osteoarthritis, Knee
- Humans
- Patient Reported Outcome Measures
- Range of Motion, Articular
- Treatment Outcome
- Patient Satisfaction
- Male
- Network Meta-Analysis as Topic
Veja também
Estudos relacionados
- Postoperative Swelling Did Not Return to Preoperative Levels in Most Patients Two Years After Total Knee Arthroplasty
- Development and validation of a clinical prediction model for patient-reported pain and function after primary total knee replacement surgery
- Efeito do alinhamento axial nos resultados dos pacientes após artroplastia total do joelho (TKR): revisão sistemática e metaanálise
- Alinhamento funcional versus alinhamento mecânico na artroplastia total do joelho: metanálise de ensaios controlados randomizados