Impacts of time pressure during the ICU handover safety check of critical care nurses: A randomised eye-tracking analysis
Emergência e Terapia IntensivaPor ScienceMed · · a partir do resumo dos autores
Resumo original em inglês
O que aconteceu
Safety checks during ICU handovers are error prone and often affected by stress, particularly time pressure. Standardized handover and safety-check procedures are lacking. We hypothesized that time pressure would negatively affect error detection and visual behaviour in ICU nurses performing handover safety checks.
We conducted a randomized eye-tracking study in April 2024 in a simulated ICU setting with a standardized patient and predefined hidden errors. All ICU nurses at our institution were invited to participate. Participants were randomized into four groups to assess the effects of time pressure and checklist use on error detection and gaze behaviour. The primary outcome was overall error recognition. Secondary outcomes included eye-tracking metrics (dwell time, entry time, revisits, and first visual intake duration) across predefined areas of interest (AOIs).
O que encontraram
Ninety-one ICU nurses were included. Overall, participants missed a median of 4 errors (IQR 3.0-5.0), including 3 major (IQR 2.0-3.0) and 2 minor errors (IQR 1.0-2.0). Under time pressure, participants missed significantly more errors (median 5.0, IQR 3.0-6.0) than those without time pressure (median 3.5, IQR 3.0-5.0; p = 0.002). Checklist availability did not significantly affect error detection, with a median of 4.5 errors missed (IQR 3.0-5.0) without a checklist versus 4.0 (IQR 3.0-5.0) with a checklist (p = 0.651). Eye-tracking analysis showed that the probability of missing errors was associated with altered gaze behaviour across all AOIs in time-pressured groups compared to non-time-pressured groups.
Por que isso importa
Time pressure significantly impaired error detection during ICU handover safety checks, whereas the use of the applied checklist was not associated with a measurable improvement in performance. Eye-tracking data demonstrated that time pressure was associated with distinct gaze behaviour patterns, suggesting altered visual attention during handovers.
Time pressure reduces error detection during ICU handovers, underscoring performance vulnerability under this condition. Strategies to reduce time pressure and assess checklist usefulness, which may improve patient safety, should be validated in further studies.
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
Impacts of time pressure during the ICU handover safety check of critical care nurses: A randomised eye-tracking analysis
Ivan Chau, Carina Graf, Patrick Zinsli, Yael van der Geest, Pedro David Wendel-Garcia, Philipp K Buehler, Urs Pietsch, Daniel A Hofmaenner
Descritores MeSH
- Eye-Tracking Technology
- Time Pressure
- Nurses
- Patient Handoff
- Critical Care Nursing
- Intensive Care Units
- Male
- Patient Safety
- Checklist
- Adult
Veja também
Estudos relacionados
- Effectiveness of a checklist for enteral medication administration: A randomized controlled trial
- Intervenções Lidas por Enfermeiros para Mitigar Erros de Medicação de Alta Alert na Atenção Crítica: Revisão Sistemática de Eficácia e Estratégias de Implementação
- Global prevalence and associated factors of turnover intention among intensive care nurses: A systematic review and meta-analysis
- Intensive Care Unit Nurses' Perceptions and Experiences of Clinical Alarms: A Systematic Review of Qualitative Evidence Using Meta-Aggregation