Impact of shortening the blanking period to 8 weeks after PVI: Insights from COMPARE-CRYO using continuous rhythm monitoring
CardiologiaPor ScienceMed · · a partir do resumo dos autores
Resumo original em inglês
O que aconteceu
Early recurrences of atrial tachyarrhythmias (ERATs) after pulmonary vein isolation (PVI) are common. While many correlate to late recurrences (LRs), some do not. The impact of ERATs timing is difficult to assess with noninvasive Holter monitoring because of undersampling. The recommended duration of the blanking period (BP) was recently shortened from 90 days to 8 weeks.
The purpose of this study was to evaluate the impact of ERATs timing after PVI and the effect of a shorter BP by using implantable cardiac monitors for continuous rhythm monitoring.
This is a prespecified substudy of the Comparison of the POLARx and the Arctic Front cryoballoon for pulmonary vein isolation in patients with symptomatic paroxysmal atrial fibrillation (COMPARE-CRYO) study, which enrolled patients with paroxysmal atrial fibrillation undergoing cryoballoon ablation. All patients underwent implantable cardiac monitor implantation, and the BP was 90 days.
O que encontraram
A total of 5285 ERATs episodes occurred in 117 of 201 patients (58%). Freedom from LR was 82% vs 37% in patients without vs with ERATs (P<.001). When patients were classified according to their last episode of ERATs occurring between days 0 and 30, between days 31 and 60, and between days 61 and 90, freedom from LR was 60%, 56%, and 11%, respectively (P<.001). Seven of 201 patients (3.4%) had AF recurrence in the third month after ablation, but not between days 91 and 365, which reclassifies them from ablation success to ablation failure with the shortened 8-week BP.
Por que isso importa
ERATs after PVI is common. The presence of ERATs in the third month after PVI was highly predictive of ablation failure, supporting the shortening of the BP to 8 weeks; however, the shorter BP reclassifies only 7 (3.4%) of patients to ablation failure instead of ablation success.
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
Impact of shortening the blanking period to 8 weeks after PVI: Insights from COMPARE-CRYO using continuous rhythm monitoring
Salik Ur Rehman Iqbal, Thomas Kueffer, Sven Knecht, Patrick Badertscher, Jens Maurhofer, Philipp Krisai, Corinne Jufer, Gregor Thalmann, Nikola Kozhuharov, Valon Spahiu et al.
Descritores MeSH
- Heart Conduction System
- Pulmonary Veins
- Heart Rate
- Atrial Fibrillation
- Electrocardiography, Ambulatory
- Cryosurgery
- Catheter Ablation
- Time Factors
- Treatment Outcome
- Male
Veja também
Estudos relacionados
- Cryoballoon Pulmonary Vein Isolation With Versus Without Additional Right Atrial Linear Ablation for Persistent Atrial Fibrillation: The CRALAL Randomized Clinical Trial
- Durability of thermal pulmonary vein isolation in persistent atrial fibrillation assessed by mandated repeat invasive study
- A Novel Visually Guided Radiofrequency Balloon Ablation Catheter for Pulmonary Vein Isolation: One-Year Outcomes of the Multicenter AF-FICIENT I Trial
- Prevalence and outcome of early recurrence of atrial tachyarrhythmias in the Cryoballoon vs Irrigated Radiofrequency Catheter Ablation (CIRCA-DOSE) study