ScienceMed®
Imagem de arquivo, ilustrativa: Epiderme e derme humanas ao microscópio óptico, coloração HE

Impact of keratinized mucosa on implant-health related parameters: A 10-year prospective re-analysis study

Gastroenterologia
Imagem de arquivo, ilustrativa — não é do estudo. Epiderme e derme humanas ao microscópio óptico, coloração HE. Kilbad · domínio público · Wikimedia Commons

Ensaio clínico randomizadoNível 2 · Nova evidênciaClinical implant dentistry and related research28 fev 202431 citações

Por ScienceMed · · a partir do resumo dos autores

Salvar

Resumo original em inglês

O que aconteceu

To investigate whether the lack of keratinized mucosa (KM) affects peri-implant health after 10 years of loading.

Data from 74 patients with 148 implants from two randomized controlled studies comparing different implant systems were included and analyzed. Clinical parameters including bleeding on probing (BOP), probing depth (PD), plaque index, marginal bone loss (MBL), and KM width (KMW) at buccal sites were collected at baseline (time of the final prosthesis insertion), 5-year and 10 years postloading. Multivariable logistic and linear regression models by means of a generalized estimated equation (GEE) were used to evaluate the influence of buccal KM on peri-implant clinical parameters; BOP, MBL, PD, and adjusted for implant type (one-piece or two-piece) and compliance.

O que encontraram

A total of 35 (24.8%) implants were healthy, 67 (47.5%) had mucositis and 39 (27.6%) were affected by peri-implantitis. In absence of buccal KM (KM = 0 mm), 75% of the implants exhibited mucositis, while in the presence of KM (KMW >0 mm) 41.2% exhibited mucositis. Regarding peri-implantitis, the corresponding percentages were 20% (KM = 0 mm) and 26.7% (KM >0 mm). Unadjusted logistic regression showed that the presence of buccal KM tended to reduce the odds of showing BOP at buccal sites (OR: 0.28 [95% CI, 0.07 to 1.09], p = 0.06). The adjusted logistic regression model revealed that having buccal KM (OR: 0.21 [95% CI, 0.05 to 0.85], p = 0.02) and using two-piece implants (OR: 0.34 [95% CI, 0.15 to 0.75], p = 0.008) significantly reduced the odds of showing BOP. Adjusted linear regression by means of GEE showed that KM and two-piece implants were associated with reduced MBL and MBL changes (p < 0.05).

Por que isso importa

The lack of buccal KM appears to be linked with peri-implant parameters such as BOP and MBL, but the association is weak. The design of one-piece implants may account for their increased odds of exhibiting BOP.

Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.

O estudo original

Impact of keratinized mucosa on implant-health related parameters: A 10-year prospective re-analysis study

Leonardo Mancini, Franz Josef Strauß, Hyun-Chang Lim, Lorenzo Tavelli, Ronald E. Jung, Nadja Naenni, Daniel Stefan Thoma

Descritores MeSH

  • Peri-Implantitis
  • Mouth Mucosa
  • Dental Implants
  • Female
  • Humans
  • Keratins
  • Male
  • Middle Aged
  • Mucositis
  • Periodontal Index

Veja também

Estudos relacionados