Evaluation of microcirculatory protection in percutaneous revascularisation: A stent implantation technique and device comparison
CirurgiaPor ScienceMed · · a partir do resumo dos autores
Resumo original em inglês
O que aconteceu
Coronary microvascular dysfunction (CMD) after percutaneous coronary intervention (PCI) is prognostically important and may also be a cause of persistent angina. The stent balloon inflation technique or material properties may influence the degree of CMD post-PCI.
Thirty-six patients with stable angina attending for elective PCI were randomized to either slow drug eluting stent (DES) implantation technique (DES slow group): +2 atm. every 5 s., maintained for a further 30 s or a standard stent implantation technique (DES std group): rapid inflation and deflation. PressureWire X with thermodilution at rest and hyperemia and optical coherence tomography (OCT) were performed pre- and post-PCI. Combined primary endpoints were changes in index of microvascular resistance (delta IMR) and coronary flow reserve (delta CFR) following PCI. The secondary endpoints included differences in cardiac troponin I (delta cTnI) at 6 h post-PCI, Seattle angina questionnaire (SAQ) at 1, 3, 6, and 12 months and OCT measures of stent results immediately post-PCI and at 3 months.
O que encontraram
Both groups were well matched, with similar baseline characteristics and OCT-defined plaque characteristics. Delta IMR was significantly better in the DES slow PCI arm with a median difference of -4.14 (95% CI -10.49, -0.39, p = 0.04). Delta CFR was also numerically higher with a median difference of 0.47 (95% CI -0.52, 1.31, p = 0.46). This did not translate to improved delta median cTnI (1.5 (34.8) vs. 0 (27.5) ng/L, p = 0.75) or median SAQ score at 3 months, (85 (20) vs. 95 (17.5), p = 0.47).
Por que isso importa
Slow stent implantation is associated with less CMD after elective PCI in patients with stable angina.
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
Evaluation of microcirculatory protection in percutaneous revascularisation: A stent implantation technique and device comparison
Muhammad Aetesam-Ur-Rahman, Tian X Zhao, Kitty Paques, Joana Oliveira, Yi-Da Chiu, Melissa Duckworth, Bharat Khialani, Stephen Kyranis, Martin R Bennett, Nick E J West et al.
Descritores MeSH
- Prosthesis Design
- Microcirculation
- Tomography, Optical Coherence
- Drug-Eluting Stents
- Coronary Circulation
- Male
- Humans
- Prospective Studies
- Female
- Middle Aged
Veja também
Estudos relacionados
- Mechanistic insights into lumen reduction after implantation of a drug-eluting bioresorbable metallic scaffold assessed with serial intracoronary imaging: from the OPTIMIS trial
- Coronary Microvascular Resistance as a Predictor of the Placebo-Controlled Response to Percutaneous Coronary Intervention: Microvascular-Stratified Analysis of ORBITA
- A randomized prospective study investigating the relationship between post-PCI wall shear stress and 12-month neointimal healing: The SHEAR-STENT study
- 5-Year Outcomes With a Novel Coronary Sirolimus-Eluting Bioresorbable Scaffold: The NeoVas Randomized Trial