Effectiveness of patent foramen ovale occlusion devices versus medical therapy: An indirect comparison based on reconstructed individual patient data
NeurologiaPor ScienceMed · · a partir do resumo dos autores
Resumo original em inglês
O que aconteceu
Percutaneous closure of patent foramen ovale (PFO) reduces the risk of recurrent stroke in selected patients with cryptogenic stroke. However, direct comparative data among different occlusion devices are lacking.
Our study aimed to compare the efficacy PFO closure plus medical therapy versus medical therapy alone in patients with cryptogenic stroke using data from randomized controlled trials (RCTs).
Randomized controlled trials with ≥36 months of follow-up evaluating PFO closure with Abbott or Gore devices versus medical therapy were identified. Individual patient data were reconstructed from published Kaplan-Meier curves using the IPDfromKM artificial intelligence-based method. Time-to-event analyses were performed using hazard ratios (HRs) with 95% confidence intervals (CIs). Between-trial heterogeneity was assessed on control arms.
O que encontraram
Three randomized trials were included. No significant heterogeneity was observed among medical therapy control groups. When all devices were pooled, PFO closure significantly reduced recurrent stroke compared with medical therapy alone (HR 0.4288; 95%CI, 0.2533 to 0.7258; p = 0.0016). Both Abbott devices (HR 0.4631 (95% CI, 0.2597 to 0.8258; p = 0.00909) and Gore devices (HR= 0.3457 (95%CI, 0.1354 to 0.8826) were associated with a significantly lower risk of recurrent stroke. The indirect comparison between devices showed no significant difference.
Por que isso importa
In this indirect comparison based on reconstructed individual patient data, PFO closure with occlusion devices significantly reduced recurrent stroke compared with medical therapy alone. Abbott and Gore devices demonstrated comparable long-term efficacy.
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
Effectiveness of patent foramen ovale occlusion devices versus medical therapy: An indirect comparison based on reconstructed individual patient data
Melania Rivano, Roberto Brunoro, Marco Cesca, Andrea Ossato, Andrea Messori
Descritores MeSH
- Ischemic Stroke
- Cardiovascular Agents
- Cardiac Catheterization
- Stroke
- Foramen Ovale, Patent
- Secondary Prevention
- Septal Occluder Device
- Patient-Specific Modeling
- Recurrence
- Risk Factors
Veja também
Estudos relacionados
- Patent foramen ovale closure vs medical therapy in secondary prevention of stroke and TIA: A systematic review and meta-analysis
- Eficácia comparativa e segurança de estratégias de terapia antiplaquetária duplas definidas pela composição do fármaco e duração do tratamento para AVC isquêmico menor agudo ou ataque isquêmico transitório de alto risco: revisão sistemática e meta-análise da rede bayesiana
- Net clinical benefit of PFO closure versus medical treatment in patients with cryptogenic stroke: A systematic review and meta-analysis
- Statin initiation and early stroke recurrence in the Platelet-Oriented Inhibition in New TIA and Minor Ischemic Stroke Trial (POINT) trial population