ScienceMed®
Imagem de arquivo, ilustrativa: Capilares da prega ungueal do dedo, em capilaroscopia

Effectiveness of conduction system pacing for cardiac resynchronization therapy: A systematic review and network meta-analysis

Cardiologia
Imagem de arquivo, ilustrativa — não é do estudo. Capilares da prega ungueal do dedo, em capilaroscopia. Dmitry Stavtsev, Nikita Margaryants e Mikhail Volkov · CC BY 4.0 · Wikimedia Commons

Revisão sistemáticaNível 1 · Evidência consolidadaJournal of cardiovascular electrophysiology28 set 202315 citações

Por ScienceMed · · a partir do resumo dos autores

Salvar

Resumo original em inglês

O que aconteceu

Cardiac resynchronization therapy (CRT) with biventricular pacing (BiV-CRT) is ineffective in approximately one-third of patients. CRT with Conduction system pacing (CSP-CRT) may achieve greater synchronization. We aimed to assess the effectiveness of CRT with His pacing (His-CRT) or left bundle branch pacing (LBB-CRT) in lieu of biventricular CRT.

O que encontraram

The PubMed, Embase, Web of Science, Scopus, and the Cochrane Library were systematically searched until August 19, 2023, for original studies including patients with reduced left ventricular ejection fraction (LVEF) who received His- or LBB-CRT, that reported either CSP-CRT success, LVEF, QRS duration (QRSd), or New York Heart Association (NYHA) classification. Effect measures were compared with frequentist network meta-analysis. Thirty-seven publications, including 20 comparative studies, were included. Success rates were 73.5% (95% CI: 61.2-83.0) for His-CRT and 91.5% (95% CI: 88.0-94.1) for LBB-CRT. Compared to BiV-CRT, greater improvements were observed for LVEF (mean difference [MD] for His-CRT +3.4%; 95% CI [1.0; 5.7], and LBB-CRT: +4.4%; [2.5; 6.2]), LV end-systolic volume (His-CRT:17.2mL [29.7; 4.8]; LBB-CRT:15.3mL [28.3; 2.2]), QRSd (His-CRT: -17.1ms [-25.0; -9.2]; LBB-CRT: -17.4ms [-23.2; -11.6]), and NYHA (Standardized MD [SMD]: His-CRT:0.4 [0.8; 0.1]; LBB-CRT:0.4 [-0.7; -0.2]). Pacing thresholds at baseline and follow-up were significantly lower with LBB-CRT versus both His-CRT and BiV-CRT. CSP-CRT was associated with reduced mortality (R = 0.75 [0.61-0.91]) and hospitalizations risk (RR = 0.63 [0.42-0.96]).

Por que isso importa

This study found that CSP-CRT is associated with greater improvements in QRSd, echocardiographic, and clinical response. LBB-CRT was associated with lower pacing thresholds. Future randomized trials are needed to determine CSP-CRT efficacy.

Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.

O estudo original

Effectiveness of conduction system pacing for cardiac resynchronization therapy: A systematic review and network meta-analysis

Hamed Tavolinejad, Sina Kazemian, Ali Bozorgi, Roman Michalski, Daniël Hoyer, Daniel Sedding, Arash Arya

Descritores MeSH

  • Heart Failure
  • Cardiac Resynchronization Therapy
  • Electrocardiography
  • Cardiac Conduction System Disease
  • Stroke Volume
  • Ventricular Function, Left
  • Treatment Outcome
  • Humans
  • Bundle of His

Veja também

Estudos relacionados